摘要 目的 :探讨电化学发光免疫分析法 (ECLIA)定量测定HBsAg的最适稀释度。方法 :采用正常混合血清倍比稀释HBsAg(+) /HBeAg(+) /HBcAb(+)、HBsAg(+) /HBeAb(+) /HBcAb(+)和HBsAg(+) /HBcAb(+)三种模式血清 ,应用ECLIA夹心法定量测定其HBsAg的含量。结果 :ECLIA法定量测定HB sAg阳性的三种血清学模式血清稀释度不同 ,HBsAg(+) /HBeAg(+) /HBcAb(+)模式存在HD HOOK效应 ,其最适稀释度为 1 :32 ;HBsAg(+) /HBeAb(+) /HBcAb(+)和HBsAg(+) /HBcAb(+)模式不需进行稀释 ,原倍血清HBsAg测定值最高。结论 :利用ECLIA法定量测定HBsAg(+) /HBeAg(+) /HBcAb(+)模式血清中HBsAg时 ,应对其血清进行预稀释 ,同时测定原倍和 1 :32稀释血清HBsAg含量 ,根据测定情况计算其结果 ,而HBsAg(+) /HBeAb(+) /HBcAb(+)和HBsAg(+) /HBcAb(+)模式 ,其血清HBsAg测定一般不需进行预稀释。 Objectives: To study the optimal dilution of serum for quantitative measuring of level of hepatitis B surface antigen (HBsAg) by electrochemiluminescence immunoassay (ECLIA). Methods: The sera from the three serological patterns [HBsAg(+)/HBeAg(+)/HBcAb(+), HBsAg(+)/HBeAb(+)/HBcAb(+) and HBsAg(+)/HBcAb(+)]were collected and diluted to a serial of different concertration with normal negtive mixed sera. The level of HBsAg was dectected by ECLIA separatedly. Results: The optimal dilution of serum for HBsAg quantitative measuring in serological pattern of HBsAg(+)/HBeAg(+)/HBcAb(+) is at 32 folds because of high does(HD)-hook effect, while HBsAg level of non-diluted specimen is higher than that of diluted ones in two other serological patterns. Conclusions: In ECLIA, high does(HD)-hook effect results in less reactivity and false-negative results.In order to avoid the experimental misdiagnosis, it is necessary to predilute the serum specimen when the HBsAg concentrations exceed the measuring range of the ECLIA method. The results indicated that the specimen should be prediluted to 32 folds when measure the serum of HBsAg level in HBsAg(+)/HBeAg(+)/HBcAb(+) serological pattern, while there is no need to measuring of HBsAg level in two other serological patterns.
出处 《承德医学院学报》 2004年第1期17-20,共4页 Journal of Chengde Medical University
关键词 电化学发光免疫分析法 定量测定 HBSAG 最适稀释度 Hepatitis B virus surface antigen ECLIA Serological patterns associated HBsAg positive Optimal dilution HD-HOOK effect
  • 相关文献

参考文献4

  • 1骆抗先.乙型肝炎基础和临床:第2版[M].北京:人民卫生出版社,2001.194.
  • 2中华医学会传染病与,寄生虫病学分会,肝病学分会.病毒性肝炎防治方案[J].中华肝脏病杂志,2000,8(6):324-329. 被引量:14009
  • 3朱平安 郭奕明 徐汉平 等.电化学发光免疫分析法定量测定乙肝表面抗原的初步评价.中华现代中西医杂志,2003,1(6):487-487.
  • 4朱平安 朱红秋 申群喜 等.HBV血清学标物不同模式与HBV-DNA含量的关系[J].中华医学研究杂志,2003,3(11):967-967.

共引文献14016

同被引文献54

引证文献6

二级引证文献37

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部