期刊文献+

聚乙烯及交联聚乙烯水树老化的特性研究 被引量:8

Study of Characters of Water Tree Aged PE and XLPE Slice
下载PDF
导出
摘要 为了解聚乙烯和交联聚乙烯电缆水树老化机理,并为电缆水树老化状态的检测与监测技术奠定实验和理论基础,对聚乙烯和交联聚乙烯片状试样进行了水树老化实验,研究了交联聚乙烯和聚乙烯片状试样老化前后损耗角正切tanδ及损耗电流I与外施电压V的关系变化。结果表明,老化后损耗角正切随外施电压的变化而变化,且损耗电流与外施电压的关系呈现非线性。 In order to understand water tree aging mechanism of PE cables and XLPE cables and ground technology of diagnosis water tree of cables in experiment and theory, experiments of water tree aged PE and XLPE slice are carried out. In this paper, the relationships between loss and voltage, loss current and voltage of water tree aged PE and XLPE slice are studied.And it is found that loss changes vs varied voltages and the relation between loss current and voltage is nonlinear when PE and XLPE slice are water tree aged.
出处 《哈尔滨理工大学学报》 CAS 2004年第2期82-84,89,共4页 Journal of Harbin University of Science and Technology
关键词 交联聚乙烯 水树 老化 损耗角 损耗电流 电力电缆 绝缘 XLPE PE water tree character
  • 相关文献

参考文献4

二级参考文献8

  • 1[1]S.Hvidsten et al.Understanding Water Treeing Mechanisms in the Development of Diagnostic Test Methods.IEEE Transactions on Dielectric and Insulation,1988,5(5):754~759
  • 2[2]Kenichi Hirotsu et al.Development of Hot-line Diagnosis Method for XPE Cables by Measurement of Harmonics Current.Proceedings of 1994 International Joint Conference:26th Symposium on Electrical Insulation Materials,September 26~30,1994 Osaka,Japan:455~458
  • 3[3]Jean-Pierre Crine.Electrical,Chemical and Mechanical Processes in Water treeing.IEEE Transactions on Dielectric and Insulation,1998,5(5):681~693
  • 4[1]Hvidsten S, Ildstad E, Sletbak J. Importance of understanding water treeing mechanisms in the development of diagnostic test methods[J]. IEEE Transaction on DEI, 1998,(3):754-760.
  • 5[2]Shnoda C et al. A consideration of DC leakage current peak in XLPE cables[A]. Proceedings of the 5th international conference on properties and application of dielectric materials[C].Seoul, Korea, 1997. 362-355.
  • 6[3]Bulinski A, So E, Bamji S et al. Diagnostic measurement of high voltage insulation using current comparator technology[EB/OL]. http//www. power. inms. ca/group/fullpapaers/isci94.htm
  • 7[4]Kenichi Hirotsu et al. Development of hot-line diagnostic method for XLPE cables by measurement of harmonics current[A]. Proceedings of Japan-China conference on electric insulation diagnosis[C]. Osaka, Japan, 1994. 455-459.
  • 8[5]Moore W J, Miljanic P N. The current comparator[M]. Peter peregrinus Ltd., IEE Electric Measurement Series 4. 1988.295-297.