摘要
用水、盐,聚氯乙烯粉和羧甲基纤维钠四种材料配制成一种适用的微波体模(模拟肌肉组织)。该体模的复介电系数在300~2500MHz范围内与实际人体肌肉组织的误差≤5%。这种体模的优点是材料立足国内,价廉,室温下配制,使用方便。本文也给出这种体模的温度特性,稳定性和热学特性,供电磁场生物效应和微波热疗等研究使用。
<ABSTRACT>
A new kind of microwave phantom muscle tissue was developed. The
ingredients for the phantom muscle tissue consist of water, salt, polyvin-
yl chloride powder and cellulose carboxymethalate.
The differences of permittivities between the phantom and actuanl
muscle are less than 5%for 300-2500MHz The advantages of the
phantom muscle tissue are low-cost and easy to prepare at room tempere
ure. The characteristics of the phantom muscle tissue are also given.
出处
《中国生物医学工程学报》
EI
CAS
CSCD
北大核心
1992年第3期199-204,共6页
Chinese Journal of Biomedical Engineering
基金
国家自然科学基金资助课题
关键词
体模
微波
介电系数
电磁吸收剂量
: Phantom tissue
Microwave
Permittivity Specific absorption rate