秦岭隧道钢纤维喷混凝土衬砌质量控制 被引量:2

Quality control of steel fiber shotcrete lining in Qinling tunnel
下载PDF
导出
摘要 在秦岭隧道采用钢纤维喷混凝土衬砌的施工中 ,由于严格按秦岭隧道标准和有关设计文件要求进行原材料和配比的选择以及施工质量的检验 ,取得了良好的效果。 During the construction of Qinling tunnel steel fiber shotcrete was used for lining with good results obtained since the work was carried out strictly according to the standards of the tunnel and relative document requirements concerning the selection of materials and the proportion of concrete as well as engineering quality inspection. The paper presents the method of inspection for the engineering quality of steel fiber shotcrete lining in Qinling tunnel and the corresponding requirements. Finally some experiences are summarized.
出处 《现代隧道技术》 EI 2004年第2期68-75,共8页 Modern Tunnelling Technology
关键词 秦岭隧道 钢纤维喷混凝土衬砌 质量检验 Qinling tunnel Steel fiber shotcrete lining Quality inspection