期刊文献+

不同免疫分析仪在环孢素A血药浓度监测中的差异 被引量:7

Study on the difference between AxSYM and TDx in cyclosporin A monitoring
下载PDF
导出
摘要 目的 :考察不同分析方法对环孢素A(CsA)血药浓度监测中的影响。方法 :71例肝肾移植术后CsA样品分别用AxSYM和TDx测定。结果 :TDx监测结果大于AxSYM监测结果。结论 :AxSYM和TDx在环孢素A血药浓度监测中存在差异。 OBJECTIVE To examine the effect of assay methodology on variability in blood concentrations.METHODS CsA was analyzed for 71 samples from patients with liver or kidney transplants using TDx and AxSYM respectively.RESULTS The results were summarized as TDx > AxSYM.CONCLUSIONS There are differences observed in blood concentrations obtained from AxSYM and TDx.
出处 《中国医院药学杂志》 CAS CSCD 北大核心 2004年第4期222-224,共3页 Chinese Journal of Hospital Pharmacy
关键词 环孢素A 治疗药物监测 荧光偏振免疫法 cyclosporin A therapeutic drug monitoring FPIA
  • 相关文献

参考文献14

  • 1Pierre EW, Kathy A. Evaluation of the new AxSYM cyclosporine assay: comparison with TDx monoclonal whole blood and emit cyclosporine assays[J].Clin Chem, 1999,45 (3) : 432.
  • 2Werner S. Perfommnce and specificity of monoclonal immunoassays for cyclosporine moniloring: How specific is specific [J].Clin Chem, 1999,45(3) :371.
  • 3Copeland KR, Yatscoff RW. Immunosuppre.ssive activity and toxicity of cyclosporine metabolites characterized by mass spectro.scopy and nuclear magnetic resonance[J].Transplant Proc,1990,22:1146.
  • 4Copeland KR, Yatscoff RW, Mc Kenna R. Immunosuppressive activity of cyclosporine metabolites compared and characterized by nmss spectroscopy and nuclear magnetic resonance[J ]. Clin Chem, 1990,36(2) :225.
  • 5Lensmeyer GL, Wiebe DA, Carlson IH, et al. Concentrations of cyclosporin A and its metabolites in human tissues postmortem [J]. J Anal Toxicol, 1991,15(3):110.
  • 6Ekkehard S, Dobrin S, Maria S, et al. Cyclosporin whole blood immunoassays (AxSYM, CEDIA, and Emit ): a critical overview of performance characteristics and comparison with HPLC [J]. Clin Chem, 1998,44(10):2158.
  • 7Oellerich M, Armstrong VW. Two-hour cyclosporine concentration determination: An appropriate tool to monitor neural therapy? [J].Ther Drug Monit, 2002,24 ( 1 ) :40.
  • 8Pierre EW, Kathy A. Evaluation of the new AxSYM cyclosporine assay: comparison with TDx monoclonal whole blood and emit cyclosporine assays[J]. Clin Chem, 1999,45(3):432.
  • 9Werner S. Performance and specificity of monoclonal immunoassays for cyclosporine monitoring: How specific is specific[J]. Clin Chem, 1999,45(3):371.
  • 10Copeland KR, Yatscoff RW. Immunosuppressive activity and toxicity of cyclosporine metabolites characterized by mass spectroscopy and nuclear magnetic resonance[J]. Transplant Proc, 1990,22:1146.

同被引文献74

引证文献7

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部