期刊文献+

600MW机组锅炉分割屏爆管原因分析 被引量:1

Analyses the Burst Reason for Radiant Partial Division Walls of 2020t/h Type Boiler
下载PDF
导出
摘要 通过对电厂实时监测系统的历史数据、锅炉受热面布置方式、分割屏联箱结构、燃烧运行特性的分析,认为2020t/h锅炉分割屏爆管的主要原因是分割屏位置距火焰中心太近,设计面积偏大,机组长期参与调峰,调峰频率大,低负荷运行时间长。提出了防止分割屏爆管的技术措施和建议:减少机组调峰频率、提高最低运行负荷、降低分割屏管壁温度报警定值、加强炉膛吹灰、调整燃烧器喷口位置、优化燃烧、控制启停速度等。 Analysis the burst reasons for radiant superheater partial of 2020t/h type boiler, The main reasons is that partial division walls are designed so closed to the burner center, the area of partial division walls is bigger than it needed, the units always suits for apex and valley, and in the most time running with a low load. The author puts forward some corresponding technical proposals and the advice to avoid division walls burst; reduce the times of apex and valley, increase the basic load, reduce the alarm value of division wall's metal temperature, strong the vapor blower, optimize the boiler combustion and control the speed of start-up and load-down.
出处 《现代电力》 2004年第2期7-12,共6页 Modern Electric Power
基金 中国华电国际电力公司技术项目
关键词 邹县发电厂 600MW机组 锅炉 分割屏过热器 爆管 受热面 实时监测系统 boiler partial division walls burst analyses