期刊文献+

利用Monica质控图进行ELISA操作考核的探讨 被引量:4

Discuss to the Exam of ELISA Operation Via Monica Quality Control Chart
下载PDF
导出
摘要 目的 探讨ELISA操作考核方法。方法 以HBsAg低值质控血清ELISA定性检测为例 ,用Monica质控图进行操作考核。 结果 根据Monica质控图中垂线长短及中点所处的位置 ,可以判断被考核者检测结果的精密度与准确度。结论 用Monica质控图进行ELISA操作考核 ,方法实用 ,简便可行。 Objective To discuss the exam way to enzyme-linked immunoadsorbent assay (ELISA) operation. Methods Operation exams were carried out via Monica quality control chart in ELISA test of HBsAg low value quality control sera.Results The accuracy of the test result of the operator was determined, according to the length of the perpendicular and the location of the midpoint in Monica quality control chart. Conclusion It is convenient and helpful that Monica quality control chart is used in the exam of ELISA operation.
出处 《临床军医杂志》 CAS 2004年第1期95-96,共2页 Clinical Journal of Medical Officers
关键词 Monica质控图 ELISA 操作考核 考核方法 检测 酶联免疫吸附试验 Monica quality control chart enzyme-linked immunoadsorbent assay operation exam
  • 相关文献

参考文献1

二级参考文献2

共引文献6

同被引文献15

引证文献4

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部