摘要
在理论分析的基础上,根据当前电站热交换管道检测存在的实际问题,设计制作了相应的试样,通过试验分析和实践应用,证明了声脉冲管道检漏在电站检测中应用的有效性,并根据实践经验提出检测过程应该注意的具体事项。
Samples were designed based on academic analysis and investigation on problems in checking the heat exchanging tubes in power slation.With experiment in laboratory and application on sile,sonic pulse for inspection tubes in power station were found effective and could solve the existent problems.
出处
《江西电力》
2004年第1期43-44,48,共3页
Jiangxi Electric Power
关键词
声脉冲
管道
检漏
电站
检测
仪器应用
sonic pulse
power station
tube
check
detect
instrument