期刊文献+

灰库区域除灰仪用压缩空气系统改造 被引量:1

Retrofitting of instrument compressed air system in the ash silo area
下载PDF
导出
摘要 叙述扬州第二发电有限责任公司灰库区域除灰仪用压缩空气系统长期存在的灰库空压机故障率高和灰库仪用压缩空气含水量大的问题,并分析其原因及危害。介绍针对这些问题对该系统进行优化改造所采取的措施,对改造后该系统的运行方式及维护提出具体要求。对该系统改造后所产生的社会和经济效益进行评估。 High failure rate of air compressors and high water content in the instrument compressed air ever existed for a long time in the ins- trument compressed air system of ash silo area in the ash handling system of Yangzhou No.2 Power Generation Co. This paper analyzes the causes and harm of these problems; hriefs The taken measures for optimization and retrofitting in light of these problems; puts forward the concrete requirements of retrofitted system for operation mode and maintenance; and finally estimates the social and economic benefit gained from the retrofit.
作者 解其林
出处 《中国电力》 CSCD 北大核心 2004年第4期81-83,共3页 Electric Power
关键词 锅炉 除灰系统 除灰仪 压缩空气系统 技术改造 灰库区域 扬州第二发电有限责任公司 ash silo air compressor instrument compressed air retrofit
  • 相关文献

参考文献4

  • 1Design instructions for erection operation and maintenance of ash hand lingsystem[S]. United Conveyor Company, 1996.
  • 2George Babcock, Stephen Wilcox. STEAM/its generation and use(40th edition) [M]. Babcock & Wilcox, 1992.
  • 3唐海宁.锅炉运行规程[S].[S].扬州第二发电有限责任公司,2001..
  • 4解其林.锅炉检修规程[S].[S].扬州第二发电有限责任公司,2001..

同被引文献14

引证文献1

二级引证文献1

相关作者