摘要
选择典型的装有分体空调的居室和办公室 ,对新风不同引入方式下冬夏室内的环境参数作了测试 ,比较并分析了新风引入方式对室内热环境、空气品质、噪声、空调能耗及运行经济性的影响 。
Measures the indoor environmental parameters o f typical residential buildings and offices with split air conditioning systems in different fresh air supply modes in summer and winter. Compares and analyses the indoor thermal environment, air quality, noise, energy consumption and econom ics in different fresh air supply modes. Points out that fresh air supply with sensible heat exchangers has remarkable environmental and economical benefits.
出处
《暖通空调》
北大核心
2004年第3期66-69,共4页
Heating Ventilating & Air Conditioning
关键词
分体空调
室内环境
新风
热环境
空气品质
噪声
fresh air, indoor environment, split air conditioning system, energy consumption