期刊文献+

冷水大温差对表冷器及风机盘管性能的影响 被引量:23

Influence of chilled water with large temperature difference on performance of air coolers and fan coils
下载PDF
导出
摘要 指出冷水大温差可以减少冷水泵的能耗 ,但同时使表冷器和风机盘管的性能降低。运用多元回归方法 ,分别建立了表冷器和风机盘管的数学模型 ,得到其在大温差下的性能方程 。 Chilled water with large temperature difference can reduce energy consumption of pumps but worsen the performance of air cooler and fan coil. Using multiple regression method, establishes mathematical models for air coolers and fan coils respectively and obtains their performance equations under large tempe rature difference conditions. Quantitatively analyses the influence of chilled w ater with large temperature difference on cooling capacity and dehumidifying eff ects of air coolers and fan coils.
作者 于丹 陆亚俊
出处 《暖通空调》 北大核心 2004年第3期77-79,共3页 Heating Ventilating & Air Conditioning
关键词 表冷器 风机盘管 冷水 大温差 数学模型 去湿能力 large temperature difference, air cooler, fan coil, dehumidifying effect
  • 相关文献

参考文献2

  • 1韩伟国 陆亚俊.风机盘管加新风系统设计[A]..见:2000年全国暖通空调制冷学术年会论文集[C].,2000..
  • 2严德隆,张维君.空调蓄冷应用技术.北京:中国建筑工业出版社,1997