摘要
归纳了高位水箱与气压水罐相比下的优点,论证了水箱的设置高度,推荐了设置气压供水装置解决高位水箱出水压力不能满足最不利点消火栓水压要求问题的方法。
This article summarizes the advantages of high-level water tank over air pressure water pot, demonstrates the set height of water tank, and recommends to use the air pressure water supply devices in high-level water tank enable the water outlet pressure of high-level water tank to meet water pressure demands of the hydrant most-unfavorable point.
出处
《煤矿现代化》
2004年第1期28-29,共2页
Coal Mine Modernization
关键词
高位水箱
气压水罐
多层建筑
消防系统
气压供水装置