期刊文献+

不同年龄人工耳蜗置入患者术后心理物理测试比较 被引量:7

The psychophysical tests in different age of patients with cochlear implants
原文传递
导出
摘要 目的 :对不同年龄使用人工耳蜗患者的心理物理测试进行分析和比较。方法 :共有 170例使用澳大利亚 2 4M型人工耳蜗系统的患者参加本次试验。将患者按年龄分为A(<3岁 )、B(3~ <6岁 )、C(6~ 12岁 )、D(>12岁 ) 4组。心理物理测试主要包括阈值和舒适阈的测试。结果 :开机后 1个月 ,A组与D组患者各电极 (除2 0号电极 )的舒适阈的差异均有统计学意义 (P <0 .0 1,其中 2、18、19、2 1、2 2号电极P <0 .0 5 )。开机时 ,D组患者实际使用舒适阈与舒适阈差值的标准化值的均值与A、B、C组患者的均值之间的差异均有统计学意义 (P <0 .0 1,其中与C组的差异P <0 .0 5 )。开机 1周时 ,D组患者实际使用舒适阈与舒适阈差值的标准化值的均值与A组的均值之间的差异有统计学意义 (P <0 .0 5 )。结论 :不同年龄患者的心理物理测试存在差异。患者使用人工耳蜗系统的早期 ,不同年龄患者实际使用舒适阈与舒适阈差值的标化值的差异有统计学意义。 Objective: The aim of this research is to analyse and compare the psychophysical tests in different age of patients with a cochlear implant. Method:One hundred and seventy patients with Nucleus CI24M cochlear implant system participated in this study. The patients were divided into four groups according to their age. They were group A (<3 year), B(3-<6 year), C(6-12 year) and D(>12 year). The psychophysical tests included T and C-Level evaluation. Result:C-Levels of each electrode (except electrode No.20) were significantly different between group A and D at the time of one month after switch-on (P< 0.01 , P< 0.05 for the No. 2, 18, 19, 21, 22 electrode). The normalized differences between used C-Levels and C-Levels for group D were significantly higher than the other three groups at the switch-on session (P< 0.01 ,P< 0.05 between group D and C). The normalized differences between used C-Levels and C-Levels were significantly different for the group A and D at one week after first programming session (P< 0.05 ). Conclusion:T and C-Level for different age groups were different. The normalized differences between used C-Levels and C-Levels were significantly different among the four groups in the few weeks after switch-on.
出处 《临床耳鼻咽喉科杂志》 CSCD 北大核心 2004年第4期215-218,共4页 Journal of Clinical Otorhinolaryngology
关键词 人工耳蜗 心理物理测试 Cochlear implant Psychophysical test
  • 相关文献

参考文献4

  • 1Saunders E,Cohen L,Aschendorff A,et al.Threshold,comfortable level and impedance changes as a function of electrode-modiolar distance[].Ear Hear.
  • 2Brown C J,Abbas P J,Bertschy M,et al.Longitudinal assessment of physiological and psychophysical measures in cochlear implant users[].Ear and Hearing.1995
  • 3Franck K H,Shah U K,Marsh R R,et al.Effects of Clarion electrode design on mapping levels in children[].Annals of Otology Rhinology Laryngology.2002
  • 4McKay C M,Remine M D,McDermott H J.Loudness summation for pulsatile electrical stimulation of the cochlea: effects of rate, electrode separation, level, and mode of stimulation[].The Journal of The Acoustical Society of America.2001

同被引文献49

引证文献7

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部