摘要
提出了双嘧达莫与高锰酸钾和罗丹明B的化学发光新体系 ,并发现表面活性剂吐温 80可显著增强该体系的化学发光 ,据此建立了流动注射化学发光测定双嘧达莫的新方法。该方法选择性好 ,灵敏度高 ,线性范围宽 ,双嘧达莫在 5 0× 10 -8~ 5 0× 10 -5g·mL-1范围内与发光信号呈线性关系 ,检出限 1 7× 10 -8g·mL-1,RSD为 1 1% (n =11,cs=1 0× 10 -6g·mL-1双嘧达莫浓度 )。
A new system for the determination of dipyridamole with flow injection chemiluminescence was described. It is based on the chemiluminescence reaction of dipyridamole-potassium permanganate with rhodamine B. Tween-80 was found to be an enhancer of the chemiluminescence reaction. A method based on the enhanced chemiluminescence for dipyridamole determination has been developed. The method has high sensitivity, selectivity and good repeatability with a linear concentration range of 5.0 x 10(-8)-5.0 x 10(-5) g(.)mL(-1), a detection limit of 1.7 x 10(-8) g(.)mL(-1) and a RSD of 1.1% (n = 11, c(s) = 1.0 x 10(-6) g(.)mL(-1)).
出处
《光谱学与光谱分析》
SCIE
EI
CAS
CSCD
北大核心
2004年第3期278-280,共3页