期刊文献+

带有可更换半自准工作电极的集成化毛细管电泳安培检测芯片 被引量:6

An Integrated Capillary Electrophoresis-Amperometric Detection Chip with Replaceable and Quasi-self-aligned Working Electrode
下载PDF
导出
摘要 A glass capillary electrophoresis microchip with integrated amperometric detection cell equipped by replaceable micro-disk working electrode is described. The detection cell was fabricated as a buffer reservoir on the microchip. A micro-electrode-guiding hole, which was in alignment with the exit of the separation channel, was drilled into the bottom edge of the chip. When a micro-disk copper working electrode, the outside diameter of which being matched with the inside diameter of the guiding hole, was inserted into the hole, passed through detection cell and finally got access to the exit of the separation channel, the electrode could be quasi-self-aligned to the channel exit and fixed inside the guiding hole without the help of a micro-positioner. Thus an integrated end-column amperometric detection system with replaceable disk working electrode was established on the microchip. Good reproducibility of the electrode alignment was demonstrated by a 4 1% RSD in the detection of sucrose after repeated(n=9) alignment of a micro-copper disk electrode. The developed michrochip was used for separation and detection of oligosaccharides. A glass capillary electrophoresis microchip with integrated amperometric detection cell equipped by replaceable micro-disk working electrode is described. The detection cell was fabricated as a buffer reservoir on the microchip. A micro-electrode-guiding hole, which was in alignment with the exit of the separation channel, was drilled into the bottom edge of the chip. When a micro-disk copper working electrode, the outside diameter of which being matched with the inside diameter of the guiding hole, was inserted into the hole, passed through detection cell and finally got access to the exit of the separation channel, the electrode could be quasi-self-aligned to the channel exit and fixed inside the guiding hole without the help of a micro-positioner. Thus an integrated end-column amperometric detection system with replaceable disk working electrode was established on the microchip. Good reproducibility of the electrode alignment was demonstrated by a 4 1% RSD in the detection of sucrose after repeated(n=9) alignment of a micro-copper disk electrode. The developed michrochip was used for separation and detection of oligosaccharides.
出处 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 2004年第5期844-846,共3页 Chemical Journal of Chinese Universities
基金 国家自然科学基金(批准号 :2 0 2 990 3 0 )资助
关键词 微流控芯片 毛细管电泳 安培检测 半自准工作电极 集成化 Microfluidic chip Capillary electrophoresis Amperometric detection
  • 相关文献

参考文献2

二级参考文献10

  • 1[2]McCreedy T. Tends Anal. Chem., 2000, 19:396~401
  • 2[3]Manz A, Becker H .(Eds) Microsystem Technology in Chemistry and Life Sciences, Springer, Berlin, 1999:12~13
  • 3[4]Duffy D C, McDonald J C, Schueller O J A, Whitesides G M. Anal.Chem., 1998, 70:4974~4984
  • 4[5]Simpson P C, Woolley A T, Mathies R A. J.Biomed. Microdev., 1998, 1:7~26
  • 5[6]Stjerstroem M, Roeraade J. J. Micromech. Microeng., 1998, 8:33~38
  • 6[7]Fang Q,Xu G M,Fang Z L. Anal.Chem., 2002, 74: 1223~1231
  • 7[11]Kopp M U, Demello A J, Manz A. Science, 1998, 280:1046~1048
  • 8[12]Neudeck G W, Pierret R F. (Eds) Introduction to Microelectronic Fabrication, (Modular Series on Solid State Devices,V.5), Addison-Wesley Publishing Company, Massachusetts, 1993
  • 9金亚,罗国安,汤扬华,周兆英.集成毛细管电泳芯片系统的制作、测试及应用[J].分析科学学报,2001,17(2):148-152. 被引量:17
  • 10方肇伦,方群.微流控芯片发展与展望[J].现代科学仪器,2001,18(4):3-6. 被引量:68