摘要
以常规热平衡方法为基础,将等效热降法应用于压水堆核电机组二回路热力系统汽水流量的分配计算,计算结果与常规热平衡法完全相同,并可简捷快速地计算出热力系统连接方式以及局部参数变化对汽水流量分配的影响,为压水堆核电机组二回路热力系统应用热力学第二定律进行定量分析奠定了基础。
In this paper the authors apply equivalent heat drop method to the steam-water flow distribution calculation for the secondary-cucirt thermodynamic system of PWR power plant,based on the normal energy balance method.The calculation result by those method is identical completely.The deciding quantity alculation can be fast made specially because of the thermodynamic system link mode and local parameters change,and foundation for the deciding quantity analyses by thermodynamic second law is established.
出处
《汽轮机技术》
北大核心
2004年第2期94-96,共3页
Turbine Technology
关键词
压水堆核电机组
二回路
等效热降
汽水流量
计算
PWR nuclear power plant
secondary-cucirt
equivalent heat drop method
steam-water flow
calculation