摘要
通过对兰州石化公司化肥厂低温甲醇洗脱碳部分换热器进行核算和分析,探讨低温甲醇洗系统换热器的设计方法,并评价现场各换热器的实际操作性能。
This article works out and analyses the cost of the Rectisol CO2 removal section heat exchangers in Shell Oil Gasification plant and tries to find out a suitable heat exchanger design method, and then assesses each existing heat exchanger operating performance in the plant.
出处
《大氮肥》
CAS
2004年第1期20-24,共5页
Large Scale Nitrogenous Fertilizer Industry