摘要
大亚湾核电站为 2X980MW机组 ,2号发电机出现密封油泄漏而 1号发电机发生了密封瓦烧熔等问题。分析了发电机漏密封油和密封瓦烧熔的原因 ,并提出了处理措施。
For the two 980MW unites at Daya Bay nuclear power station, the leakage of sealing oil for generator was found in unit one and the sealing ring of the generator was burned in unit two.The reasons of leakage of generator sealing oil and the burning of the generator’s sealing ring were analyzed.a method was put forward to resolve those problems.
出处
《润滑与密封》
CAS
CSCD
北大核心
2004年第3期116-118,共3页
Lubrication Engineering
关键词
核电站
发电机
密封系统
泄漏
密封瓦
烧熔
generator sealing oil
leakage
sealing ring
burned
trouble-shooting