期刊文献+

基于膨胀特性的厌氧流化床反应器的设计和运行控制 被引量:1

Design and operation control of anaerobic fluidized bed reactor based on bed expansion
下载PDF
导出
摘要 生物流化床的床层膨胀行为直接与生化反应区的水动力学和效率相关 ,床层膨胀特性是进行合理设计和运行的重要依据。目前流化床设计一般没有考虑生物膜的影响 ,但生物颗粒的流化行为有别于光滑载体 ,因此需要对曳力系数Cd 和膨胀特性方程中的ui 进行必要的修正。在综合分析基础上 。 The expansion of biological fluidized bed has a strong relationship with hydraulic dynamics and efficiency in biochemical reaction zone, bed expansion characteristics are fundamentally important for us to design and run liquid solid biological fluidized bed. Present fluidized bed designs do not consider the effect of biofilm, but the fluidization of bioparticles is different to that of smooth carriers, thus terminal free fall velocity u i in Richardson Zaki equation and drag coefficient C d should be modified. Based on synthetic analysis, the paper presents the procedure and method for optimizing fluidized bed design and operation.
出处 《环境污染治理技术与设备》 CSCD 北大核心 2004年第4期84-87,共4页 Techniques and Equipment for Environmental Pollution Control
关键词 厌氧流化床反应器 床层膨胀 污水处理技术 活性碳 反硝化 biological fluidized bed design and operation wastewater treatment bed expansion
  • 相关文献

参考文献27

  • 1Weber W J ,et al. Physical-chemical treatment of wastewater.J Wat Pollut Control Fed, 1970,42 ( 1 ) : 83 - 87.
  • 2Khang S J , et al. A practical wake model for estimating bed expansion and holdup in three phase fluidized systems. AIChE Symp Series, 1983,222 : 47 - 54.
  • 3Diez Blanco,et al. Effects of biofilm growth, gas and liquid velocity on the expansion of an anaerobic fluidized bed reactor( AFBR). Wat Res , 1995,29 (7) : 1649 - 1654.
  • 4Richardson J F, et al. Sedimentation and fluidisation. Part 1 Trans Instn Chem Eng , 1954,32 : 35 - 53.
  • 5Leo T Mulcahy. et al. Fluidization and reactor bionass characteristics of the denitrification fluidized bed biofilm reactor. Wat Res, 1987,21 (4) :451 - 458.
  • 6Klangduen Pochana, et al. Model development for simultaneous nitrification and denitrification. Wat Sci Tech, , 1999,39 ( 1 ) :235 - 243.
  • 7C R G Tavares, et al. The effect of air superficial velocity on biofilm accumulation in a three phase fluidized bed reactor.Wat Res ,1995,29(10) :2293 - 2298.
  • 8P Marin, et al. Design and startup of an anaerbic fluidized bed reactor. Wat Sci Tech, 1999,40 (8) : 63 - 70.
  • 9Csikor I , et al. New interpretation of expansion in biofilm-coated particle fluidization. Appl Microbiol Biotechnol,1994,41:608 - 614.
  • 10Cristiano Nicolella, et al. Terminal settling velocity and bedexpansion characteristics of biofilm-coated particles. Biotechnology and Bioengineering, 1999,62( 1 ) :62 - 70.

二级参考文献1

  • 1蔡平(译),气液固流态化工程,1993年

共引文献3

同被引文献24

  • 1USEPA. Integrated Water Quality Monitoring and As- sessment Report Guidance Memorandum [ EB/OL ]. ht- tp://water. epa. gov/lawsregs/lawsguidance/cwa/tmdl/ 2002wqma. cfm,2011 - 11 - 19.
  • 2Bott C B,Parker D S,Jimenez J,et al. WEF/WERF study of BNR plants achieving very low N and P limits: evaluation of technology performance and process relia-bility[ J]. Water Sci Technol,2012,65 ( 5 ) :808 - 815.
  • 3Bohz J P, Morgenroth E, Daigger G T,et al. Method to i- dentify potential phosphorus rate-limiting conditions in post-denitrification biofilm reactors within systems de- signed for simultaneous low-level effluent nitrogen and phosphorus concentrations [ J]. Water Res, 2012, 46 (19) :6228 - 6238.
  • 4Jeong J, Hidaka T, Tsuno H, et al. Development of bio- logical filter as tertiary treatment for effective nitrogen re- moval : biological filter for tertiary treatment [ J ]. Water Res,2006 ,40(6) : 1127 - 1136.
  • 5Jokela J P Y, Kettunen R H,Sormunen K M,et al. Bio- logical nitrogen removal from municipal landfill leachate: low-cost nitrification in biofihers and laboratory scale in- situ denitrification [ J ]. Water Res, 2002,36 ( 16 ) : 4079 - 4087.
  • 6Aesoy A,Odegaard H,Bach K,et al. Denitrification in a packed bed biofilm reactor (BIOFOR)--Experiments with different carbon sources [ J ]. Water Res, 1998,32 ( 5 ) : 1463 - 1470.
  • 7Puznava N, Zeghal S, Redder E. Simple control strategies of methanol dosing for post-denitrification[ J]. Water Sci Technol, 1998,38 ( 3 ) :291 - 297.
  • 8Yun Z,Choi E,Han Y T. Polishing of BNR process ef- fluent by tertiary denitrifying filter[ J]. Water Sci Tech- nol, 1997,36(12) :29 - 37.
  • 9Koch G, Siegrist H. Denitrification with methanol in ter- tiary filtration [ J ]. Water Res, 1997,31 ( 12 ) : 3029 - 3038.
  • 10Farabegoli G, Gavasci R, Lombardi F, et al. Denitrifica- tion in tertiary filtration:application of an up-flow filter [J]. J Environ Sci Health(Part A),2003,38(10): 2169 -2177.

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部