期刊文献+

原子吸收分光光度法测定右旋糖酐铁注射液的含量 被引量:2

Determination of iron dextran injection by atomic absorption spectrophotometer
下载PDF
导出
摘要  建立了原子吸收分光光度法测定右旋糖酐铁注射液含量的方法,以盐酸溶液(1→100)为溶剂,检测波长248.3nm,在5~20μg/mL范围内吸收度与浓度呈良好的线性关系,r=0.9995,回收率98.8%,RSD为1.5%(n=5),稳定性好。本方法与碘量法相比,操作简便、快速,结果准确。 A method was established for the determination of iron dextran injection by atomic absorption spectrophotometer. The detection was carried out with an ultraviolet detector at 248.3 nm. The linearity was in the range of 2~20 μg/mL with r=0.999 5, the average recovery was 98.8% with 1.5% of RSD. The method was proved to be simple, rapid and precise. This method may be used for the quality control of iron dextran injection.
作者 唐棣
出处 《中国兽药杂志》 2004年第4期17-18,共2页 Chinese Journal of Veterinary Drug
关键词 右旋糖酐铁 含量测定 原子吸收分光光度法 注射液 吸收度 determination atomic absorption spectrophotometer iron dextran injection
  • 相关文献

参考文献1

  • 1.GB/T13885-92.饲料中铁、铜、锰、锌、镁的测定方法[S].,..

同被引文献12

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部