期刊文献+

应用电化学免疫传感器检测大片形吸虫抗原抗体反应的研究 被引量:6

Studies on the Antigen-antibody Reactions of Fasciola gigantica by Using Electrochemical Immunosensor
下载PDF
导出
摘要 应用电化学免疫传感器,以恒电位法检测了大片形吸虫的抗原抗体反应,结果表明,该传感器可应用于大片形吸虫的抗原抗体反应的检测,阳性血清与阴性血清的电流响应曲线具有明显的离散度;初步试验表明,该法的检测结果相对于ELISA检测结果,其符合率为83.3%;该法还具有操作简便、检测快速、选择性好等特点,测定一个样品用时不到1h,每测一个样品血清用量仅10μl,与羊等多种血清无交叉反应。 Antibody-antigen reactions of Fasciola gigantica were studied by using electrochemical immunosensor with the method of voltammretry.The results indicated the sensor can be used for detecting reactions of antigen and antibody of F.gigantica effectively.Positive sera can be distinguished easily from negative sera and other sera of F.gigantica effectively.Positive sera can be distinguished easily from negative sera and other sera of domestic animals by using this sensor.The preliminary experiment showed the results obtained by this method conforming to that of ELISA is 83.3 percentage.The operation of this method is simple and quick.It needs less than one hour for detecting one sample and only consumes 10 μl serum for one time.
出处 《畜牧兽医学报》 CAS CSCD 北大核心 2004年第3期339-342,共4页 ACTA VETERINARIA ET ZOOTECHNICA SINICA
关键词 大片形吸虫 抗原抗体反应 电化学免疫传感器 检测 诊断 大片形吸虫病 Electrochemical immunosensor Fasciola gigantica Antigen-antibody reaction Detection
  • 相关文献

参考文献18

  • 1Anderson N, Luong T T, Vo N G, et al. The sensitivity and specificity of two methods for detecting Fasciola infections in cattle[J]. Vet Parasitol, 1999, 83:15-24.
  • 2Sirisriro A, Grams R, Vichasri-Grarns S, et al. Production and characterization of monoclonal antibody against recombinant fatty acid binding protein of Fasciola gigantica[J]. Vet Parasitol,2002,105:119-129.
  • 3Sobhon P, Anantavara S, Dangprasert T, et al. Fasciola gigantica: Studies of tegument as a basis for the development of immunodiagonosi and vaccine[J]. Southeas Asial J Trop Med Public Health,1998,29:387-400.
  • 4Skladal P. Advance in electrochemical immunosensor[J]. Electroanalysis, 1997, 9:737-745.
  • 5Janata J, Josowicz M. Chemical sensors[J]. Anal Chem, 1998,70:179R-208R.
  • 6Wang J. Electroanalysis and biosensors[J]. Anal Chem, 1999,71:328R-332R.
  • 7Anderson L J. Dynamic electrochemistry: methodology and Application[J]. Anal Chem, 1998,70:519R-589R.
  • 8Venkataramanan M, Pradeep T. A method to study the phase transition and desorption of self-assembled monolayers on planner gold surface[J]. Anal Chem,2000,72:5852-5856.
  • 9Pihel K, Walker Q D, Wightman R M. Overoxidized polypyrrole-coated carbon fiber microelectrodes for dopamine measurement with fast-scan cyclis voltammetry[J]. Anal Chem,1996, 68: 2084-2089.
  • 10Hansen D S, Clery D G, Estuningsih S E, et al. Immune responses in Indonesian thin tail and Merino sheep during a primary infection with Fascioal gigantica: lack of a specific IgG2 antibody response is associated with increased resistance to infection in

二级参考文献22

共引文献39

同被引文献70

引证文献6

二级引证文献29

相关作者

内容加载中请稍等...