期刊文献+

电力系统断路器遮断容量实时校核 被引量:10

Real-time check of circuit breaker interrupting capacity in power system
原文传递
导出
摘要 介绍了基于EMS的短路电流实时计算与分析,叙述了几种典型接线方式下,流经断路器的最大短路电流的求取原则,并说明了断路器遮断容量校核的方法和标准。 The real-time calculation and analysis of short-circuit current based on EMS were introduced. The cal- culation principle for maximum short-circuit current flowed through the circuit breaker under several typical connect- ing modes was expatiated. The method and standard for checking circuit breaker interrupting capacity were explained also.
出处 《华东电力》 北大核心 2004年第4期17-19,共3页 East China Electric Power
关键词 电力系统 断路器 短路电流 遮断容量 EMS 实时计算 short-circuit current circuit breaker interrupting capacity safety analysis real-time check
  • 相关文献

参考文献2

  • 1Thanh C,Nguyen,Sherman Chan,Ron Bailey,Thanh Nguyen.Auto- Check Circuit Breaker Interrupting Capabilities.IEEE Computer Applications in Power,15(1) ,Jan 2002.:24 - 28
  • 2DL/T615-1997.中华人民共和国电力行业标准:交流高压断路器参数选用导则[S].[S].,..