摘要 目的 探讨SE序列结合电影MRI对主动脉夹层的诊断价值。资料与方法 搜集主动脉夹层 17例 ,所有病例均行MRSET1WI扫描 ,其中 10例加作电影MRI,分析其MRI表现。结果  17例中 ,Ⅰ型 8例 ,Ⅱ型 6例 ,Ⅲ型 3例。SE序列和电影MRI均清楚地显示了主动脉双腔、内膜片。SE序列中 5例显示主动脉破口 ,电影MRI检查10例中 ,6例显示了主动脉破口。结论 在常规SE序列基础上 ,结合电影MRI是诊断主动脉夹层的较好方法 。 Objective To evaluate SE sequence combined with cine MRI in the diagnosis of aortic dissection.Materials and Methods SE T 1WI was performed in 17 patients with aortic dissection, and additional cine MRI was carried out in 10. MRI findings were analyzed. Results Of 17 cases, type Ⅰ was seen in 8, type Ⅱ in 6 and type Ⅲ in 3. Both SE sequence and cine MRI clearly displayed the double lumen of aorta and the intimal flap. SE sequence and cine MRI revealed entry tear in 5 and 6 cases, respectively.Conclusion The combination of SE sequence with cine MRI is very helpful for the diagnosis of aortic dissection, it provides clinicians with more valuable information.
出处 《临床放射学杂志》 CSCD 北大核心 2004年第5期393-395,共3页 Journal of Clinical Radiology
关键词 SE序列 电影MRI 诊断 主动脉夹层 Aortic dissection Mangetic renonance imaging Cine MRI
  • 相关文献

参考文献7

二级参考文献10

  • 1陈祖望,周康荣,陈福真,王述静,杨培强,沈继章,陈财忠,施伟斌.主动脉夹层几种磁共振影像的评价和比较[J].中华放射学杂志,1997,31(1):15-19. 被引量:24
  • 2Chung J M,JCAT,1994年,18卷,250页
  • 3Hirst AZ. Dissection aneurysm of the aorta: A review of 505 cases. Mdeicine, 1958, 37:217
  • 4Krinsky GA, Rofsky NM, Decorato DR,et al. Thoracic aorta: Comparison of gadolinium enhanced three-dimensional MR angiography with conventional MR imaging. Radiology, 1997, 202:183
  • 5Harthell GG. Imaging of aortic aneurysms and dissection: CT and MRI, J-Thorac-Imaging, 2001, 16:35
  • 6Prince MR. Gddolinium-enhanced MR aortography. Radiology, 1994, 191:155
  • 7Banning AP, Masani ND, Kram SI,et al. Transesophageal echoca rdiography as the sole diagnostic investigation in patients with suspected torcicaortic dissection. Br Heart J, 1994, 72:461
  • 8Richard D, White A, Obuchowski,et al. Theoracicaortic diease: Evaluation using a single MRA volume series. Journal of Computer Assisted Tomography, 1994, 18:843
  • 9James F.M. Bolus track to revolutionize constrast-enhanced MRA. Field Strength, 2000, 3:9
  • 10Underwood SR, Firmin DN, Klipstein RH,et al. Magnetic reson ance velocity mapping: Clinical application of a new tech nique. Br Heart J, 1987, 57:404

共引文献35

同被引文献9

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部