期刊文献+

中国人移植的乳内动脉平均流量测定及影响因素 被引量:12

Mean flow in internal mammary artery graft and its influencing factors in the Chinese
下载PDF
导出
摘要 目的 确定中国人非体外循环冠状动脉旁路移植术 ( OPCAB)中移植的左乳内动脉 ( L IMA)平均流量参考范围及其影响因素。 方法 对 180例冠心病患者施行 OPCAB,术中采用即时血流测量仪 ( TTFM)直接测量并记录 L IMA血流波形、搏动指数 ( PI)、平均流量、收缩期峰流量、舒张期峰流量、血管阻力、心率和平均动脉压等 ,并分析平均流量与其他因素之间的关系。 结果  180例患者移植的 L IMA流量为 2 8.19± 2 .89ml/ min,分布范围较广 ( 6~178ml/ m in) ,其中在 2 0~ 2 5 ml/ min区间内有最大分布频数 ( 39/ 180 ,2 1.7% ) ,绝大部分分布在 10~ 30 ml/ m in( 116 /180 ,6 4 .4 % )。平均流量与收缩期峰流量、舒张期峰流量和血管阻力之间有一定的相关性 ( r=0 .75 ,0 .94 ,- 0 .95 ) ,与其它因素无明显的相关性。 结论 中国人 L IMA的平均流量应 >10 ml/ min,较满意的平均流量应 >2 2 ml/ min,而舒张期峰流量与血管阻力是影响平均流量的重要因素。 Objective To analyze the mean flow in left internal m am mary artery ( L IMA) graft and the influencing factors in off- pump coronary artery bypass grafting ( OPCAB) in the Chinese. Methods One hundred and eighty patients with OPCAB were studied.Transit- tim e flowmeter( TTFM) was utilized to measure and record the L IMA's blood flow wave,pulsatility index( PI) ,value of mean flow,systolic and diastolic peak flow,vascular resistance,insufficiency ratio and mean blood pressure and to analyze the relationship between mean flow of LIMA and other factors. Results Total mean flow calculated from that of all patients was2 8.19± 2 .89ml/ min( 6 - 178 ml/ m in) .Majority m ean value ( 6 4 .4 % ) was in the range of 10 - 30 ml/ min.Statistics showed that mean flow was significantly related to systolic and diastolic peak flow and vascular resistance rather than the other factors( r=0 .75 , 0 .94 ,- 0 .95 ) . Conclusions For the Chinese,over 10 ml/ min mean flow of L IMA graftis acceptable and over 2 2 ml/ min is satisfactory.The diastolic peak flow and vascular resistance are two most important factors in influencing mean flow.
出处 《中国胸心血管外科临床杂志》 CAS 2004年第2期84-87,共4页 Chinese Journal of Clinical Thoracic and Cardiovascular Surgery
基金 中国人民解放军临床高新技术重大项目 ( 2 0 0 2 卫医字 18)~~
关键词 中国人 乳内动脉 流量测定 非体外循环冠状动脉旁路移植术 血流测量仪 Chinese Off-pump coronary artery bypass grafting Internal mammary artery Mean flow Transit-time flowmeter
  • 相关文献

参考文献12

  • 1高长青,朱朗标,李伯君,肖苍松.老年患者原位乳内动脉行冠状动脉旁路移植术112例[J].中华老年心脑血管病杂志,1999,1(1):15-17. 被引量:11
  • 2高长青,朱朗标,李伯君,李功宋,余翼飞,王冬青,肖苍松,郎利.胸膜外游离带蒂乳内动脉技术[J].中华外科杂志,2000,38(3):233-234. 被引量:17
  • 3高长青,张涛,李伯君,肖苍松,吴扬,马晓辉.OPCAB即时与关胸时乳内动脉桥血流的对比研究[J].中华胸心血管外科杂志,2003,19(3):136-138. 被引量:21
  • 4Matre K, Birkeland S, Hessevik I, et al. Comparison of transit-time and Doppler ultrasound methods for measurement of flow in aortocoronary bypass grafts during cardiac surgery. Thorac Cardiovasc Surg,1994,42(3):170-174.
  • 5D'Ancona G, Karamanoukian H L, Ricci M, et al. Graft patency verification in coronary artery bypass grafting: principles and clinical applications of transit time flow measurement. Angiology, 2000, 51(9):725-731.
  • 6Walpoth BH, Bosshard A, Genyk I, et al. Transit-time flow measurement for detection of early graft failure during myocardial revascularization. Ann Thorac Surg,1998,66(3):1097-1100.
  • 7Takami Y, Ina H. Relation of intraoperative flow measurement with postoperative quantitative angiographic assessment of coronary artery bypass grafting. Ann Thorac Surg,2001,72(4):1270-1274.
  • 8Jaber SF, Koenig SC, BhaskerRao B, et al. Role of graft flow measurement technique in anastomotic quality assessment in minimally invasive CABG. Ann Thorac Surg,1998,66(3):1087-1092.
  • 9Canver CC, Cooler SD, Murray EL, et al. Clinical importance of measuring coronary graft flows in the revascularized heart. Ultrasonic or electromagnetic? J Cardiovasc Surg (Torino),1997,38(3):211-215.
  • 10Louagie YA, Brockmann CE, Jamart J, et al. Pulsed Doppler intraoperative flow assessment and midterm coronary graft patency. Ann Thorac Surg,1998,66(4):1282-1288.

二级参考文献34

  • 1高长青,朱朗标,李伯君,肖苍松.老年患者原位乳内动脉行冠状动脉旁路移植术112例[J].中华老年心脑血管病杂志,1999,1(1):15-17. 被引量:11
  • 2Louagie YAG, Haxhe JP, Jamart J, et al. Doppler fow measurement in coronary artery bypass grafts and early postoperative clinical outcome.Thorac Cardiovasc Surgeon, 1994,42:175 - 181.
  • 3Louagie YAG, Haxhe JP, Jamart J, et al. Peroperative hemodynamic study of left internal mammary artery grafts. Thorac Cardovasc Surgeon,1995,43:27-34.
  • 4Barnea O, William P. Santamore, intraoperative monitoring of IMA flow:what does it mean? Ann Thorac Surg, 1997,63:S12- 17.
  • 5Marcus MC, Wright D, Dory C, et al. Measurtmmats of coronary velocity and reactive hyperemia in the coronary circulatian of humans. Circ Res,1981,49:877 - 891.
  • 6D' Ancona G, Karamancoklan HL, Ricci M, et al. Graft revision after transit time flow measurement in off-pump coronary artery bypass grafting.Eur J Cardiothorac Surg, 2000,17:287- 293.
  • 7Walpoth BH, Bosshard A, Genyk I, et al. Transit-time flow measurement for detection of early graft failure during myocardial revascularization. Ann Thorac Surg, 1998,66:1097- 1100.
  • 8Jaber SF, Koenig SC, BhaskerRao B, et al. Role of graft flow measuremerit technique in anastomotic quality assessment in minimally invasive CABG. Ann Thorac Surg, 1998,66:1087- 1092.
  • 9Elbeery JR, Brown PM, Chitwood WR. Intraoperative MIDCAB arteriography via the left radial artery: a comparion with Doppler ultrasound for assessment of graft patency. Ann Thorac Surg, 1998,66:51 - 55.
  • 10Calafiore AM, Gallina S, Laco A, et al. Minimally invasive marmnary artery Doppler flow velocity evaluation in minimally invasive coronary operations. Ann Thorac Surg, 1998,66:1236- 1241.

共引文献58

同被引文献133

引证文献12

二级引证文献33

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部