期刊文献+

直流调制改善交直流混联系统暂态稳定性的研究 被引量:84

RESEARCH ON IMPROVING TRANSIENT STABILITY OF AC/DC HYBRID SYSTEM BY HVDC MODULATION
下载PDF
导出
摘要 文章研究了天广交直流混联系统中天广直流双侧频率功率调制对改善该混联系统暂态稳定性的作用,并做了基于实际系统运行方式的仿真实验,仿真结果表明,直流功率调制对减小系统第1个摇摆稳定峰值的效果比较明显;还基于典型两机系统的非线性直流调制控制器,构建了天广交直流混联系统的非线性直流调制控制器,并做了将其应用于实际系统的仿真实验。经综合比较得知,两种调制方式在改善系统的暂态稳定性方面的效果是相近的,且常规的双侧频率功率调制对电网运行的适应性更好。 Tian-Guang AC/DC hybrid system is the first AC and DC parallel operation system in China. Here, the effect of the improvement of transient stability of parallel operation system by power/frequency modulations at both sides of Tian-Guang hybrid system is researched, the simulation based on the operating modes of actual system is conducted. Simulation results show that it is efficient to reduce the amplitude of the first swing to make the system stable by HVDC power modulation. In addition, a nonlinear HVDC system modulation controller derived from this kind of controller for a typical two-machine power system is developed and simulation experiments are made for the purpose to apply the controller to actual system. Compositive comparisons indicate that the effects of improving transient stability of AC/DC hybrid system by two kinds of modulation modes are similar, but conventional dual power/frequency modulation at both sides possesses better adaptability to actual AC/DC hybrid system.
出处 《电网技术》 EI CSCD 北大核心 2004年第10期1-4,共4页 Power System Technology
基金 国家电力重点科技项目(KJ00-01-01)
关键词 电力系统 暂态稳定性 交直流混联系统 直流调制 仿真系统 时域仿真 Amplitude modulation Computer simulation Electric network analyzers HVDC power transmission Nonlinear control systems Standby power systems
  • 相关文献

参考文献6

  • 1Cresap R L, Scott D N. Operating experience with modulation of the pacific HVDC inter-tie[J]. IEEE Trans on Power Apparatus andSystems, 1978, PAS-97(4): 1053-1059.
  • 2Grund C E, Bahrman M P. Dynamic performance characteristics of north American HVDC systems for transient and dynamic stability evaluations[J]. IEEE Trans on Power Apparatus and Systems, 1981,PAS-100(7): 3356-3363.
  • 3Vovos N A, Galanos G D. Enhancement of the transient stability of integrated AC/DC systems using active and reactive power modulation[J]. IEEE Trans on Power Apparatus and Systems, 1985,PAS- 104(7): 1696-1702.
  • 4Anderson P M , Fouad A A. Power system control and stability[M]. USA: The Iowa State University Press, 1977.
  • 5荆勇,任震,李柏青,马世英.天广交直流混合系统输电能力的研究[J].电网技术,2002,26(8):52-55. 被引量:18
  • 6荆勇,李立浧,任震.天广交直流系统并联运行的稳定控制[J].电力系统自动化,2002,26(1):49-52. 被引量:34

二级参考文献4

  • 1[1]DL755-2001,电力系统稳定导则[S].
  • 2[2]Jing Yong,Chao Jian,Ren Zhen. Control Schemes in Tian-Guang AC and DC parallel transmission[C]. CIGRE Proceed-ings of International Conference on Power Systems. September 3-5,2001 Wuhan,China.
  • 3荆勇,谌军,李柏青,等(Jing Yong, Chen Jun, Li Baiqing, et al). 天广交直流系统并联运行的输电能力的研究(Transmission Capacity Study for Tian-Guang AC and DC Parallel System). 见:第二十七届中国电网调度运行会议论文集(In: Proceedings of the 27th China Electric Power System Control and Operation Conference). 太原(Taiyuan): 2001
  • 4Christofersen D J, Vancers I, Elahi H, et al. A Survey of the Reliability of HVDC Systems Throughout the World During 1997-1998. In: CIGRE Session. Paris: 2000

共引文献47

同被引文献925

引证文献84

二级引证文献1683