采用铁 -冰醋酸还原体系 ,将替硝唑还原后 ,在激发波长360nm ,发射波长420nm处测定其荧光强度 ,据此建立了替硝唑的荧光光谱分析法。实验表明 ,替硝唑浓度在1.0×10-6~4.0×10-4 mol/L范围内与荧光强度呈良好的线性关系 ,相对标准偏差 (RSD)为1.2 % ,检出限达5.6×10-8 mol/L。本法测定结果与药典法基本一致 ,已用于替硝唑片剂和替硝唑葡萄糖注射液中替硝唑的测定 ,结果令人满意。
Afast and simple method for the determination of tinidazole by fluorimetry is described,involvˉingthe reduction of its nitro group to amino group by iron-glacial acetic acid and the subsequent measureˉment of its emission intensity at420nm in an aqueous solution with excitation wavelength at360nm.The calibration curve has a linear range1.0×10 -6 ~4.0×10 -4 mol/L and a detection limit of5.6×10 -8 mol/L.The relative standard deviation is1.2%.The results are in agreement with those determined by the pharmacopoeia method.The proposed method has been successfully applied to the determination of tinidazole in tablets and injections with satisfactory results.
出处
《分析测试学报》
CAS
CSCD
北大核心
2004年第3期76-79,共4页
Journal of Instrumental Analysis
基金
河南省教育厅自然科学基金资助项目 (1999150023)
河南大学资助项目 (xk01017)
关键词
替硝唑
荧光分光光度法
还原
Tinidazole
Fluorimetric spectrophotometry
Reduction