期刊文献+

运动单位电位多项参数对不同类别运动单位电位的判别分析 被引量:1

Discriminant analysis of MUP multi-parameters on different sort of MUP
原文传递
导出
摘要 目的 探讨运动单位电位 (MUP)多项参数在判定不同类别MUP中的价值。方法 选取 10例肌肉病变患者、13例神经病变患者和 2 2例正常人 ,采用棘波触发平均技术 ,获取肱二头肌、胫前肌和股内侧肌MUP的时限、波幅、面积和面积 /波幅比 4项参数 ,通过SPSS10 .0软件进行方差分析和判别分析。结果 所有肌肉MUP各参数值在 3组间的差异均有显著性意义 (P <0 .0 0 0 1) ;各参数及不同参数组合对不同类别的MUP具有不同的判别率和总回代符合率。结论 时限和面积 /波幅比对肌源性损害MUP均具有较强的判别能力 ,但时限对肌源性损害MUP的判别更具敏感性和特异性 ;面积和波幅对神经源性损害MUP均具有较强的判别能力 ,但面积对神经源性损害MUP的判别更具敏感性和特异性 ; Objective To study the value of discriminant analysis of motor unit potential(MUP) multi-parameters in differentiation of various sorts of MUP. MethodsFrom the biceps brachii, tibialis anterior and vastus medialis muscles,the duration, amplitude, area and the ratio of area to amplitude of the MUPs were obtained by use of the spike-wave triggered average technique in 10 patients with myopathic disease, 13 patients with neurogenic disease and 22 healthy adults. The data were subject to analysis of variance and discriminant analysis. ResultsThe differences among the three groups with regard to all the parameters of the MUPs recorded from all the three muscles were statistically significant ( P <0.0001). There were different correct classification rate about different parameters or parameter combinations in different sort of MUP. ConclusionDuration and area/amplitude ratio had strong discriminating power to myopathic disease, but duration had extraordinary sensitivity and specificity to myopathic disease. Area and amplitude had strong discriminating power to neurogenic disease, but area had extraordinary sensitivity and specificity to neurogenic disease. Multi-parameter combination could enhance the whole discriminating power to different sort of MUP.
作者 李支援
出处 《中华物理医学与康复杂志》 CAS CSCD 北大核心 2004年第2期85-88,共4页 Chinese Journal of Physical Medicine and Rehabilitation
关键词 运动单位电位 肌源性损害 神经源性损害 棘波触发平均技术 参数 Motor unit potential Discriminant analysis Myopathic lesion Neurogenic lesion
  • 相关文献

参考文献2

二级参考文献5

  • 1Buchthal F,Guld C,RosenfalckP.Action potential parameters in normal human muscle and their dependance on physical variables[J].Acta Physiol Scand,1954,32:200-218.
  • 2Nandedkar SD,Dumitru D,King JC.Concetric needle electrode duration measurement and uptake area[J].Muscle Nerve,1997,20:1225-1228.
  • 3Nandedkar SD,Sanders D,Stalberg E.Stimulation of concentric needle EMG motor unit potentials[J].Muscle Nerve,1988,11:151-156.
  • 4Nandedkar SD,Barkhaus PE,Sanders D,et al.Analysis of amplitude and area of concentric needle EMG motor unit action potentials[J].Electroencephalogr Clin Neurophysiol,1988,69:561-569.
  • 5Sonoo M,Stalberg E.The ability of MUP parameters to discriminate between normal and neurogenic MUPs in concentric EMG:analysis of the MUP "thickness" and the proposal of "size index"[J].Electroencephalogr Clin Neurophysiol,1993,89:291-303.

共引文献1

同被引文献10

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部