摘要
通过建立土壤蓄冷、释冷的数学模型 ,对土壤蓄冷与土壤耦合热泵集成系统进行了数值模拟。分析了盘管管材、土壤类型、蓄冷温度、流体的流量。
Based on the mathematic model of the soil cool charge and discharge system, simulates the integrated system. Analyses the influence of some factors on the operation performance of inner coil, such as coil material, soil type, charging temperature, fluid flux, coil spacing and moisture content of soil, etc.
出处
《暖通空调》
北大核心
2004年第5期1-6,共6页
Heating Ventilating & Air Conditioning
基金
国家自然科学基金资助项目 (编号 :5 0 3 780 2 4)
关键词
释冷
热泵集成系统
数值模拟
盘管
土壤蓄冷
integrated soil cool storage and ground-coupled heat pump system,cool charge, cool discharge, influencing factor