期刊文献+

眼内异物CT定位图的设计和应用 被引量:1

The clinical application of CT ocular foreign body localizating diagram
下载PDF
导出
摘要 目的 评价眼内异物CT定位图在眼内异物定位中的有效性和准确性。方法 参阅CT水平或冠状扫描序列片将显影异物按照测量结果标画在相应的眼内异物CT定位图上 ,然后根据异物所在的经线和深度进行手术摘出异物。结果  47例 ( 4 7眼 )眼内异物中 ,有 40例为眼内磁性金属异物 ,采用此法定位 ,全部迅速、准确地摘出异物。结论 眼内异物CT定位图应用在眼内异物的定位中 ,简便易行、迅速准确 ,特别适用眼内磁性金属异物定位。 Objective To evaluate the effectiveness and accuracy of CT intraocular foreign body localizating diagram Methods After CT scanning,drawing the foreign body shadow on the CT intraocular foreign body localizating diagram The intraocular foreign bodies were priecisely detected and eliminate the disturbance of ectraocular foreign bodies in actinography Results In 40 of 47 eyes suffered from intraocular metallic and magnetic foreign body,all eyes were located by CT intraocular foreign body localizating diagram and then according to our results,intraocular foreing body were removed by surgery in all cases Conclusion The diagram for ocular foreign bodies is a simple,easy,and precise method that serve intraocular foreign body location Especially for intraocular metallic and magnetic foreign body
出处 《眼外伤职业眼病杂志》 北大核心 2004年第5期293-295,共3页 Journal of Injuries and Occupational Diseases of the Eye with Ophthalmic Surgeries
关键词 眼内异物 计算机断层扫描(CT) 定位图 intraocular foreign body CT localizating diagram
  • 相关文献

参考文献9

  • 1谭家铨,翁学红,肖天林,冯运红.CT扫描与眼内异物定位[J].眼外伤职业眼病杂志,1998,20(4):289-290. 被引量:11
  • 2Prokesch R, Lakits A,Scholda C,et al.Spiral CT and conventional CT in the preoperative imaging of intraocular metal foreign bodies[J]. Radiologe, 1996,38(8) :667-740.
  • 3Lakits A,Prokech R,Scholda C,et al. Muhiplanar imaging in the preoperative assessment of metallic intraocular foreign bodies. Helical computed tomography venus conventional computed tomography [J]. Ophtimlmolngy,1998,105(9) : 1679-1763.
  • 4Weiss MJ, Hofeldt AJ, Behrens M, et al. Ocular siderosis.Diagmosis and management [ J ]. Retina, 1997,17(2) : 105-113.
  • 5张效房.眼内异物的定位与摘出[M](第二版)[M].北京:科学出版社,2000.41-43.
  • 6Prokesch R,Lakits A,Scholda C,et al.Spiral CT and conventional CT in the preoperative imaging of intraocular metal foreign bodies [ J ].Radiologe,1998,38(8) :667-740.
  • 7Lakits A,Prokesch R,Scholda C,et al.Multiplanar imaging in the preoperative assessment of metallic intraocular foreign bodies.Helical computed tomography versus conventional computed tomography [ J ].Ophthalmology,1998,105(9):1679-1763.
  • 8Weiss MJ,Hofeldt AJ,Behrens M,et al.Ocular siderosis.Diagmosis and management[J].Retina,1997,17(2):105-113.
  • 9张效房.眼内异物的定位与摘出[M]第二版[M].北京:科学出版社,2000.41-43.

共引文献10

同被引文献2

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部