摘要
采自粤东柘林湾 3个站位的表层沉积物样品 ,分别在 115℃的条件下 ,用王水消化 2 4 h(A法 ) ,和经双氧水处理后 ,在 15 0℃的条件下用王水消化 ,将消化液蒸至近干两次 (B法 ) ,ICP- AES相同条件下同时测定 Fe、Mn、 Cu、Zn、Pb、Cr、Ni、Co、Cd。统计结果表明 :A法消化所测得的 Cr、Pb、Zn、Fe显著高于 B法 ,Cd、Co、Mn、Ni两法测得结果无显著差异。A法所用试剂量少 ,空白值低 ,消化条件稳定 ,对近海沉积物中各重金属元素的提取率高 ,是一种较为可靠的近海沉积物常规消化方法。
Three surface sediment samples, collected from Zhelin Bay, Guangdong province, were digested by aqua regia for 24h at the temperature of 115℃ (method A), and treated by H 2O 2 and then digested by aqua regia at the temperature of 150℃. The digested solution was vaporized for two times (method B). The concentration of Fe、Mn, Cu, Zn, Pb, Cr, Ni, Co and Cd were measured by the method of ICP-AES The statistical result showed that total contents of Cr, Pb, Zn and Fe measured were significantly higher while using method A than that while using method B, and the contents of Cd, Co, Mn, Ni were of no significant differences while using both methods. The method A was a reliable routine method for digesting offshore sediments, which uses little reagent, and has low blank value, and high extracting rate for all kinds of heavy metals in offshore sediments.
出处
《海洋技术》
北大核心
2004年第2期35-37,67,共4页
Ocean Technology
基金
广东省重大科技兴海资助项目 ( A2 0 0 0 0 5 F2 0 )
广东省自然科学基金 ( 0 2 12 60 )