期刊文献+

具有独立气路的液氦温区G-M型二级脉管制冷机性能研究

INVESTIGATION ON THE FONCTION OF THE TWO-STAGE G-M PULSE TUBE CRYOCOOLER WITH THE TEMPERATURE REGION OF LIQUID HELIUM OF SEPARATE GAS CIRCUITS
下载PDF
导出
摘要 研究了一台具有独立气体回路的液氦温区G -M型二级脉管制冷机的制冷性能。目前的实验装置由两套独立的单级双向进气型脉管系统构成 ,第一级冷头对第二级进气的预冷通过安装在第二级回热器中部的换热器与一级冷头之间的热联接来实现。研究表明 ,该制冷机采用4 He为工质 ,分别以LeyboldCP4 0 0 0和RW 2氦压缩机来驱动第一级和第二级 ,可以获得 2 18K的最低无负荷制冷温度 ,4 2K提供的最大制冷量为 5 95mW。 In this paper, the refrigeration function of a two-stage G-M pulse tube cooler with the temperature rgeion of liquid helium of separate gas circuits is studied. The current experimental apparatus consists of two parallel separate single-stage double-direction entering-gas pulse tube stages, one as the first stage precools the other, which is implemented by thermally connecting the heat exchanger in the middle of the 2nd stage regenerator to the cold end of the 1st stage. With 4He as the working fluid,the 1st and 2nd stage is driven by Leybold CP4000 and RW2 helium compressing machine respectly,a minimum no-load refrigerating temperature of 2.18K is obtained. The maximum refrigerating capacity which is offered by 4.2 K is 595 mW.
出处 《低温工程》 CAS CSCD 北大核心 2004年第2期11-17,35,共8页 Cryogenics
基金 DAAD(德国学术交流中心 )资助 国家自然科学基金 教育部高校博士点专项基金 (2 0 0 10 335 0 10 )资助
关键词 液氦温区 独立气路 G-M型二级脉管 脉管制冷机 制冷性能 liquid helium region pulse tube cryocooler independent gas circuits
  • 相关文献

参考文献16

  • 1Radebaugh R. Cryocoolers for superconductors. WE-Heraeus-Seminar,Challenges of Applied Cryoelectrics Ⅱ , Weilburg, Germany, 2003
  • 2Burt W W, Chan C K. New mid-size high efficiency pulse tube coolers. Cryocoolers, 1997, (9): 173
  • 3Ravex A, Poncet J M, Charles I,et al. Development of low frenquency pulse tube refrigerators. Adv. Cryog. Eng. , 1998, 43A: 1957 - 1964
  • 4Thummes G, Bender S, Heiden C. Approaching the 4He lambda line with a liquid nitrogen precooled two-stage pulse tube refrigerator. Cryogenics, 1996, 36(9): 709 -711
  • 5Wang C, Thummes G, Heiden C. Performance study on a two-stage 4K pulse tube cooler. Adv. Cryog. Eng. , 1998, 43A:.2055 -2062
  • 6Gao J L, Matsubara Y. Experimental investigation on 4 K pulse tube refrigerator. Cryogenics, 1994, 34:25 - 33
  • 7Wang C, Thummes G, Heiden C. A two-stage pulse tube cooler operating below 4 K. Cryogenics, 1997, 37:159 - 164
  • 8Chen G B, Qiu L M, Zheng J Y, et al. Experimental study on a double-orifice two-stage pulse tube refrigerator. Cryogenics, 1997, 37:271- 273
  • 9Zhu S W, Ichikawa M, Nogawa M,et al. Two-stage 4 K pulse tube refrigerator. Cryocooler 2001 (11) :243
  • 10Wang C, Thummes G, Heiden C. Experimental study for staging method for two-stage pulse tube refrigerators for liquid 4 He temperatures. Cryogenics 1997,37:857 - 863

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部