摘要 目的 评估使用麻气体吸附对异氟醚吸入全麻的病人苏醒和对手术室污染状况的影响。方法  30例病人 ,ASAⅠ -Ⅱ拟行异氟醚吸入麻醉。麻醉气体的吸附器安装在回路中 ,在苏醒阶段将活瓣打开 ,同时记录苏醒时间、血流动力学和血气分析各项指标。以上病人例在麻醉进行当中 ,废气排气口接废气吸收器 ,同时记录吸附器前后麻醉气体的浓度 ,计算麻醉气体的吸附率。结果 病人在清醒期苏醒时间明显缩短 ,与没有用麻醉吸附器相比 ,麻醉吸附器可以明显降低排入手术室麻醉气体的浓度。使用过程中 ,各项血流动力学指标和血气分析指标均正常。结论 麻醉气体吸附器的使用可以明显提高手术室的空气质量 ,同时在麻醉恢复期。病人的苏醒时间明显缩短而且安全可靠。 Objective To evaluate the effects of applying anesthetics waste gasabsorber, an activated charcoal filter, to removing isoflurane. Methods Thirty patients,undergong general anesthesia with isoflurane,were enrolled in this study. During awake time,the waste gas absorber located at the breath cyclesystem of anesthesia machine.Awake time,blood dynamic change and blood analysis were recorded.The gas samples were taken at the waste gas outlet of anesthetic machine, to identify the concentrations of isoflurane before and afterthe application of anesthetics waste gas absorber.The absorb rate were calculated according to those data. Results The awake time were shorten significantly,compared with those before the absorber application, isoflurane concentrations in anesthetic waste gas decreased significantly following the absorber application (P<0.01) Conclusion The application of anesthetics waste gas absorber can greatly improve the air quality in operating room and awake time was reduced greatly.
作者 王新强
出处 《江西医药》 CAS 2004年第2期88-90,共3页 Jiangxi Medical Journal
  • 相关文献

参考文献7

  • 1Dahm SL,Steptoe P,Luttropp HH.Reinstrup PCharcoal as an airwary isoflurane reflection filter.Eur J Anaesthesiol,1998,15(2):230
  • 2Imberti R,Preseglio A,Quiros E,et al.Low flow anaesthesia reduces occupational exposure to inhalation anaesthetics.Enviromentl and biological measurement in opiating room personnel.Acta Anaesthesiol Scand.1995,39(5) :586
  • 3Hojkjaer Larsen V,Severinsen I,Wasben J.Removal of halogenated anaesthetics from a closd circle system with a charcoal filter.Acta Anaesthesliol Scand,1989,33(5) :374
  • 4孙岩军 赵钢 李长杰.回路内麻醉气体吸附器对低流量麻醉苏醒时的影响[J].临床麻醉学杂志,2004,16(4):179-179.
  • 5Romano E,Auci A,Absorption of volatile anesthetics on activated charcoal.Efficiency of an experimsetal filter during low-flow circuit ventilation.Minerva Anestesiol.1995,61(10) :437
  • 6孙新艳,王俊科,马支媛,许国忠,谢妮,张晓芃,刘扬.麻醉废气吸附器清除氮氧化物和氟化物效果的观察[J].中华麻醉学杂志,2000,20(9):524-525. 被引量:4
  • 7Baungarten RK.Siaple charcoal filter for closed circuit anesthesia.Anesthesiology.1985,63( 1 ):125

二级参考文献1

共引文献3

同被引文献18

  • 1王大波,姚卫兵.应用气相色谱仪测定活性碳吸附安氟醚废气的实验研究[J].中华麻醉学杂志,1993,13(1):57-59. 被引量:5
  • 2杨文卿,黄丽芳,林定.吸入全麻的废气污染与控制措施[J].国际医药卫生导报,2005,11(6):125-126. 被引量:9
  • 3陈渝,史长宁,张崇建.呼吸机应急调用的气源通用转接头制作与应用[J].医疗卫生装备,2006,27(7):79-79. 被引量:5
  • 4Coleman MA, Coles S, Lytle T, et al. Prevention of almospheric contamination during isoflurane sedation. Clin Intensive Care,1994, 5 (5): 217~220.
  • 5Mark C R. Principles and practice of anesthesiology. Missouri:Mosby-Year Book Ine, 1993. 1012.
  • 6Tortosa SJ, Mulero C, Hernandez PJ, Analisis biblimoetrico de los articulos originales publicados en la Revista Espanola. Rev Esp Anesthesiol Reanim, 1998, 45 (6): 214.
  • 7Edward A, Ernst EA. Use of charcoal to rapidly decrease depth of anesthesia while maintaining a closed circuit. Anesthesiology,1982, 57 (4): 343.
  • 8Romano E,Pegoraro M,Vacri A,et al.Low-flow anaesthesia systems,charcoal and isoflurane kinetics[J].Anaesthesia,1992,47(12):1098-1099.
  • 9Hojkjaer LV,Severinsen I,Waaben J.Removal of halogenated anaesthetics from a closed circle system with a charcoal filter[J].Acta Anaesthesiol Scand,1989,33(5):374-378.
  • 10Reber A,Schumacher P,Urwyler A.Effects of three different types of management on the elimination kinetics of volatile anaesthetics.Implications for malignant hyperthermia treatment[J].Anaesthesia,1993,48(10):862-865.

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部