期刊文献+

下颈椎内固定技术与生物力学和解剖学的相关性 被引量:1

Correlation of lower cervical fixation with biomechanics and anatamy
下载PDF
导出
摘要 近20多年来,下颈椎的内固定技术有了长足的发展,这主要得益于颈椎外科生物力学和解剖学的研究进展。目前,下颈椎前路内固定技术以带锁钉的限制性钢板固定占主导地位,而下颈椎后路则以侧块钢板和椎弓根系统固定占主导地位,但椎弓根固定系统在生物力学上更具优势。只要熟悉颈椎的解剖并规范手术操作绝大多数的并发症是可以避免的。
出处 《中国临床康复》 CSCD 2004年第17期3338-3339,共2页 Chinese Journal of Clinical Rehabilitation
  • 相关文献

参考文献34

  • 1Spivak JM, Chen D, Kummer FJ. The effect of locking fixation screws on the stability of anterior cervical plating. Spine 1999; 24:334 - 8
  • 2Ryken TC, Clausen JD, Traynelis VC, et al. Biomechanicai analysis of bone mieral density, insertion technique, screw torque, and holding strengh of anterior cervical plate screws. J Neurosurg 1995; 83:325 - 9
  • 3Coe JD, Warden KE, Stutterlin CE 3rd, et al. Biomechanical evaluation of cervical spinal stabilization mothods in human cadaveric model. Spine 1989; 14:1122 -31
  • 4Zdeblick TA, Cooke ME, Wilson D, et al. Anterior cervical discectomy, fusion,aand plating. Spine 1993; 18: 1794- 83
  • 5Connolly PJ, Esses SI, Kostuik JP. Anterior cervical fusion: Out-come analysis of patients used with and without anterior cervical plates. J Spinal Disord 1996; 9:202 - 6
  • 6Lowery GL, McDonough RF. The significance of hardware failure in anterior cervical plate fixetion. Spine 1998; 23:181 -6
  • 7Smith MD, Emery SE, Dudley A, et al. Vertebral antery injury daring anterior decompression of the cervical spine. A retrospective review of ten patients. J Bone Joint Surg Br 1993; 75:410 - 5
  • 8Ebraheim NA, Lu J, Brown JA, et al. Vulnerability of vertebral antery in anterolateral decompression for cervical spondylosis. Clin Orthop 1996; (322):146 -51
  • 9Pait TG, Killefer JA, Arnautovic KI. Surgical anatomy of the anterior cervical spine: the disc space, vertebral antery, and associated bony structures. Neurosurgery 1996; 39:769 - 76
  • 10Oga M, Yuge Ⅰ, Terada K, et al. Tortuosity of the vertebral artery in patients with cervical spondylotic myelopathy: risk factor for the vertebral artery injury during anterior cervical decompression . Spine 1996; 21: 1085 - 9

二级参考文献44

  • 1高雨仁,杨桂姣,阎八一,马迅,马景昆,张建中.颈椎后路关节突-椎弓根联合内固定的解剖学基础[J].解剖学杂志,1994,17(6):477-480. 被引量:14
  • 2[1]Miller RM, Ebraheim NA,Xu R, et al. Anatomic consideration of transpedicular screw placement in the cervical spine. Spine, 1996,20:2317- 2322.
  • 3[2]Leconte P. Fracture et luxation desdeux premieres vertebras cervicales,in Judet R (ed): Luxation Congenenitale de la Hanche. Fractures du Cou - de - pied Rachis Cervical. Actualites de Chirurgie Orthopedique de lHospital Raymond - Poicare, Vol 3. Paris: Masson et Cie, 1994,pp 147 - 166.
  • 4[3]Saillant G,Bleynie JF. Fracture des pedicules de l'axis,in Roy -Camille R (ed) :Rschis Cervical Traumatique Non Neurologique. Pathologie Traumatique de l 'Epauke et de la Ceiture Scapulaire. Paris: masson, 1979, pp88 - 98.
  • 5[4]Borne GM, Bedou GL, Pindaudeau M. Treatment of pedicular fractures of the axis: A clinical study and screw fixation technique. J Neurosurgery,1984,60:88 -93.
  • 6[5]Abumi K,Itoh H,Taneichi H,et al. Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine:description of the techniques and preliminary report. J Spinal Disorders, 1994 7,19-28.
  • 7[6]Abumi K, Kaneda k:Pedicle screw fixation for nontraumatic lesions of the cervical spine . Spine, 1997,22:1853 - 1863
  • 8[7]Jeanneret B, Gebhard JS, Magerl F. Transpedicular screw fixation of articular mass fracture - separation: Results of an anatomical study and operative technique. J Spinal Disorders, 1994 7,222 - 229.
  • 9[10]Ebraheim NA,Xu R,Lin D,et al. Quantitative anatomy of the transverse foramen and pedicle of the axis. J Spinal Disorders.
  • 10[12]Karaikovic EE, Daubs MD, Madsen RW,et al. Morphologic characteristics of human cervical pedicles. Spine, 1997,22:493 - 500.

共引文献134

同被引文献10

  • 1李必文,袁锋伟,谭文甫.一种新型颈椎椎弓根置钉定位器的研制[J].医疗装备,2006,19(1):14-16. 被引量:4
  • 2Richter M, Cakir B, Schmidt R, et al. Cervical pedicle screws: conventional verus computer assisted placement of cannulated screws. Spine, 2005, 30: 2280-2287.
  • 3Ludwig SC, Kowalski JM, Edwards CC, et al. Cervical pedicle screws : comparative accuracy of two insertion techniques. Spine, 2000, 25 : 2675-2681.
  • 4Ludwig SC, Kramer DL, Balderston RA, et al. Placement of pedicle screws in the human cadaveric cervical spine : comparatice accuracy of three techniques. Spine, 2000, 25 : 1655-1667.
  • 5Kast E, Mohr K, Richter HP, et al. Complications of transpedicular screw fixation in the spine. Eur Spine J, 2006, 15: 327-334.
  • 6Mao GP, Zhao JN, Wang YR, et al. Design of cervical pedicle locator and three-dimensional location of cervical pedicle. Spine, 2005, 30: 1045-1050.
  • 7Seichi A, Takeshita K, Nakajima S, et al. Revision Cervical spine surgery using transarticular or pedicle screws under a computer-assisted image-guidance system. J Orthop Sci, 2005, 10 : 385-390.
  • 8Holly LT, Foley KT. Peroutaneous placement of posterior cervical screws using three-dimensional fluoroscopy. Spine, 2006, 31 : 536-541.
  • 9Acosta FL, Thompson TL, Campbell S, et al. Use of intrao- perative isocentfic C-arm 3D fluoroscopy for sextant percutaneous pedicle screw placement : case report and review of the literature. Spine J, 2005, 5.. 339-343.
  • 10Johnson RM, Hart DL, Simmons EF, et al. Cervical orthosis: a study comparing their effectiveness in restricting cervical motion in normal subjects. J Bone Joint Surg (AM), 1977, 59: 332-339.

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部