1Spivak JM, Chen D, Kummer FJ. The effect of locking fixation screws on the stability of anterior cervical plating. Spine 1999; 24:334 - 8
2Ryken TC, Clausen JD, Traynelis VC, et al. Biomechanicai analysis of bone mieral density, insertion technique, screw torque, and holding strengh of anterior cervical plate screws. J Neurosurg 1995; 83:325 - 9
3Coe JD, Warden KE, Stutterlin CE 3rd, et al. Biomechanical evaluation of cervical spinal stabilization mothods in human cadaveric model. Spine 1989; 14:1122 -31
4Zdeblick TA, Cooke ME, Wilson D, et al. Anterior cervical discectomy, fusion,aand plating. Spine 1993; 18: 1794- 83
5Connolly PJ, Esses SI, Kostuik JP. Anterior cervical fusion: Out-come analysis of patients used with and without anterior cervical plates. J Spinal Disord 1996; 9:202 - 6
6Lowery GL, McDonough RF. The significance of hardware failure in anterior cervical plate fixetion. Spine 1998; 23:181 -6
7Smith MD, Emery SE, Dudley A, et al. Vertebral antery injury daring anterior decompression of the cervical spine. A retrospective review of ten patients. J Bone Joint Surg Br 1993; 75:410 - 5
8Ebraheim NA, Lu J, Brown JA, et al. Vulnerability of vertebral antery in anterolateral decompression for cervical spondylosis. Clin Orthop 1996; (322):146 -51
9Pait TG, Killefer JA, Arnautovic KI. Surgical anatomy of the anterior cervical spine: the disc space, vertebral antery, and associated bony structures. Neurosurgery 1996; 39:769 - 76
10Oga M, Yuge Ⅰ, Terada K, et al. Tortuosity of the vertebral artery in patients with cervical spondylotic myelopathy: risk factor for the vertebral artery injury during anterior cervical decompression . Spine 1996; 21: 1085 - 9
2[1]Miller RM, Ebraheim NA,Xu R, et al. Anatomic consideration of transpedicular screw placement in the cervical spine. Spine, 1996,20:2317- 2322.
3[2]Leconte P. Fracture et luxation desdeux premieres vertebras cervicales,in Judet R (ed): Luxation Congenenitale de la Hanche. Fractures du Cou - de - pied Rachis Cervical. Actualites de Chirurgie Orthopedique de lHospital Raymond - Poicare, Vol 3. Paris: Masson et Cie, 1994,pp 147 - 166.
4[3]Saillant G,Bleynie JF. Fracture des pedicules de l'axis,in Roy -Camille R (ed) :Rschis Cervical Traumatique Non Neurologique. Pathologie Traumatique de l 'Epauke et de la Ceiture Scapulaire. Paris: masson, 1979, pp88 - 98.
5[4]Borne GM, Bedou GL, Pindaudeau M. Treatment of pedicular fractures of the axis: A clinical study and screw fixation technique. J Neurosurgery,1984,60:88 -93.
6[5]Abumi K,Itoh H,Taneichi H,et al. Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine:description of the techniques and preliminary report. J Spinal Disorders, 1994 7,19-28.
7[6]Abumi K, Kaneda k:Pedicle screw fixation for nontraumatic lesions of the cervical spine . Spine, 1997,22:1853 - 1863
8[7]Jeanneret B, Gebhard JS, Magerl F. Transpedicular screw fixation of articular mass fracture - separation: Results of an anatomical study and operative technique. J Spinal Disorders, 1994 7,222 - 229.
9[10]Ebraheim NA,Xu R,Lin D,et al. Quantitative anatomy of the transverse foramen and pedicle of the axis. J Spinal Disorders.
10[12]Karaikovic EE, Daubs MD, Madsen RW,et al. Morphologic characteristics of human cervical pedicles. Spine, 1997,22:493 - 500.
2Richter M, Cakir B, Schmidt R, et al. Cervical pedicle screws: conventional verus computer assisted placement of cannulated screws. Spine, 2005, 30: 2280-2287.
3Ludwig SC, Kowalski JM, Edwards CC, et al. Cervical pedicle screws : comparative accuracy of two insertion techniques. Spine, 2000, 25 : 2675-2681.
4Ludwig SC, Kramer DL, Balderston RA, et al. Placement of pedicle screws in the human cadaveric cervical spine : comparatice accuracy of three techniques. Spine, 2000, 25 : 1655-1667.
5Kast E, Mohr K, Richter HP, et al. Complications of transpedicular screw fixation in the spine. Eur Spine J, 2006, 15: 327-334.
6Mao GP, Zhao JN, Wang YR, et al. Design of cervical pedicle locator and three-dimensional location of cervical pedicle. Spine, 2005, 30: 1045-1050.
7Seichi A, Takeshita K, Nakajima S, et al. Revision Cervical spine surgery using transarticular or pedicle screws under a computer-assisted image-guidance system. J Orthop Sci, 2005, 10 : 385-390.
8Holly LT, Foley KT. Peroutaneous placement of posterior cervical screws using three-dimensional fluoroscopy. Spine, 2006, 31 : 536-541.
9Acosta FL, Thompson TL, Campbell S, et al. Use of intrao- perative isocentfic C-arm 3D fluoroscopy for sextant percutaneous pedicle screw placement : case report and review of the literature. Spine J, 2005, 5.. 339-343.
10Johnson RM, Hart DL, Simmons EF, et al. Cervical orthosis: a study comparing their effectiveness in restricting cervical motion in normal subjects. J Bone Joint Surg (AM), 1977, 59: 332-339.