摘要
本文介绍了在攀钢热轧板厂两座加热炉上成功使用的燃烧控制系统 ,对核心环节双交叉限幅串级比例控制原理予以了详细说明 ,作为成功范例 ,值得推广。
In this article will introduce combustion control system that satisfactorily used in two reheating furnaces in Pangang Hot Strip Mill, and explain the principle of cascade scale control with double crossing limit range detailedly. As a good example should be popularized.
出处
《四川冶金》
CAS
2004年第3期40-42,共3页
Sichuan Metallurgy
关键词
轧钢加热炉
燃烧控制系统
温度
流量
双交叉限幅串级比例控制
reheating furnace,combustion control,temperature,flow,cascade scale control with double crossing limit range