期刊文献+

光扫描型pH图象传感器测试条件的研究与分析 被引量:5

High-Spatial Resolution Light Scanning Two-Dimension pH-Imaging Sensor and Its Imaging
下载PDF
导出
摘要 以LAPS为基础 ,研究高分辨率光扫描型二维pH图象传感器及其测量系统 ,重点研究了传感器的芯片材料与测试条件对传感器输出光电压的影响 ,并给出优化参数。在此基础上对溶液二维pH值分布进行了测量 ,并给出溶液pH值二维分布的灰度图。 The main work is to research high resolution light scanning two-dimension pH image sensor based on EIS structure,and use this sensor measuring system to measure the two-dimension distribution of pH value of the solution. The structure of sensor chip and the system to realize the measure for pH value,the effects of measurement conditions on output photovoltage for the sensor are studied mainly.Based on all above work, the two-dimension distribution of the pH value of the solution is measured and the map of two-dimension pH distribution of the certain solution can be drawn in different gray levels.
出处 《传感技术学报》 CAS CSCD 2004年第2期205-208,共4页 Chinese Journal of Sensors and Actuators
基金 国家自然科学基金资助项目 (6 0 176 0 2 8)
关键词 高分辨率 光扫描型 pH图象传感器 二维pH值分布 灰度 pH-Imaging Sensor two-dimension distribution of pH value high resolution light scanning gray level
  • 相关文献

参考文献8

  • 1Bergfeld P.Development of an ion-sensitive solid-state device for neurophsiological measurement[J].IEEE Trans.1970,BME-17:70-71.
  • 2Engstrom R C,et al.Fluorescence imaging of electrode-solution interfacial process [J].Anal.Chem.1992,64:2525-2528.
  • 3Bove M,et al.An array of H+-FETS for space-resolved electrochemical measurements in micro-enviroments[J].Sensors and Actuators.1995,B24-25:218-221.
  • 4Hafeman D G,et al.Light-addressable potentiometric sensor for biochemical systems[J].Science.1998,240(4856):1182-1185.
  • 5野村聪.pH测定の新展开[J].蛋白质核酸酵素,1998,9:79-86.
  • 6中尾基.微小领域二次元pH分布可视化のための光走查型化学显微镜[J].Bunseki Kagaku,1998,6:369-373.
  • 7林立.高分辨率LAPS对溶液pH值二维分布的研究[M]硕士研究生毕业论文[M].天津:南开大学,2003.17-22.
  • 8林立旻,牛文成,赵煜,喻骏,秦艳.LAPS对溶液pH值二维分布测量的研究[J].南开大学学报(自然科学版),2003,36(4):11-15. 被引量:3

二级参考文献5

  • 1野村聪.pH测定の新展开[J].蛋白质核酸酵素,1998,9:79-86.
  • 2Parak W J, George M, Gaub H E, et al. The field-effect-addressable potentiometric sensor/stimulator(FAPS)-a new concept for a surface potential sensor and stimulator with spatial resolution [J]. Sensors and Actuators, 1999,B58: 497~498.
  • 3中尾基.微小领域二次元pH分布可视化のための光走查型化学显微镜[J].Bunseki Kagaku,1998,6:369-373.
  • 4邵丙铣 张永夏.离子敏场效应器件的界面电势[J].电子学报,1988,1:60-61.
  • 5Startore M, Adami M, Nicolinietal C. Minority carrier diffusion length effects on light addressable potentiometic sensor (LAPS) device[J]. Sensors and Actuators, 1992, A32(3) :432~436

共引文献3

同被引文献61

  • 1魏金宝,韩泾鸿,张虹,徐磊.基于LAPS的生化多参数检测仪表的研制[J].仪器仪表学报,2004,25(z1):283-285. 被引量:5
  • 2林立旻,牛文成,赵煜,喻骏,秦艳.LAPS对溶液pH值二维分布测量的研究[J].南开大学学报(自然科学版),2003,36(4):11-15. 被引量:3
  • 3许改霞,徐莹,刘清君,蔡华,李燕,李蓉,王平.光寻址单细胞传感器的设计及药物检测的研究[J].中国生物医学工程学报,2006,25(4):465-471. 被引量:4
  • 4孙志斌,陈佳圭.锁相放大器的新进展[J].物理,2006,35(10):879-884. 被引量:38
  • 5Bove M, Cambiaso A, Grattarola M , et al. An array of H^+ FETS for space-resolved electrochemical measurements in micro-enviroments [J]. Sensors and Actuators , 1995,B24-25 : 218- 221.
  • 6Hafeman D G, Parce J W, McConell HW. Light-addressable potentiometric sensor for biochemical systems [J].Science, 1998 , 2140(4856) :1182- 1185.
  • 7Bergfeld P. Development of an ion-sensitive solid-stage device for neurophsiological measurement[J]. IEEE Trans,1970,BME-17 : 70- 71.
  • 8Engstrom R C, Ghaffari S, Qu H. Fluorescence imaging of electrode-solution interacial process[J]. Anal Chem,1992,64 : 2525- 2528.
  • 9Hafeman D G,Parce J W,McConnell H W. Light-addressable potectiometic sensor for biochemical system [ J ]. Science, 1988 (240) : 1182 -1185.
  • 10Liu Qingiun, Cai Hua, Xu Ying, et al. Olfactory cell-based biosensor:A first step towards a neurochip of bioelectronic nose [ J ]. Biosensors and Bioelectronics ,2006 (22) :318 -322.

引证文献5

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部