摘要 以地表水热源热泵作为研究对象,建立了间接膨胀式地表水热源热泵系统的数学摸型,并利用水源热泵实验装置,进行了夏季制冷、冬季供暖的实验研究,得出夏季制冷时平均性能系数COP=3.1,冬季供暖时平均性能系数COP=2.6,验证了地表水热源热泵用于夏季制冷和冬季供暖,理论上是可行的。 The heat pump system that utilized surficial water as a resource was studied and the mathematical model of the indirect expanding system was built in the paper. The experimental results show that the main coefficients of performance ((COP)) are 3.1 and 2.6 respectively under cooling in summer and heating in winter.
出处 《青岛大学学报(工程技术版)》 CAS 2004年第2期14-18,共5页 Journal of Qingdao University(Engineering & Technology Edition)
关键词 地表水 热源 热泵 数学模型 surficial water heat source heat pump mathematical model
  • 相关文献

参考文献4

  • 1(德)库伯 斯泰姆莱 王子介 译.热泵的理论与实践[M].中国建筑工业出版社,1986..
  • 2Stefanuk N B M,Aplevich J D,Renksizbulut M.Modeling and simulation of a superheat controlled water-to-water heat pump [J].ASHRAE Trans,1992,98(2):172-184.
  • 3Darby M I,Gribbons J R.Temperature variations near pipes used as a so il source for heat pump [J].Energy Research,1987(2):171-177.
  • 4Votsis P P,Tassou S A,Wilson D R,et al.Dynamic characteristics of an air-to-w ater heat-pump system [J].Int J Refrig,1992,15(2):89-94.

同被引文献14

  • 1陈超,倪真,李小宁,宋文军,尚春鸽.住宅建筑中闭式水源热泵空调系统的应用研究[J].暖通空调,2004,34(6):72-77. 被引量:14
  • 2曲云霞,杨勇,李爱景.水源热泵机组变工况性能的实验研究[J].山东建筑大学学报,2007,22(3):222-225. 被引量:12
  • 3Chen X, Zhang G Q, Peng J G, et al. Analysis on energy consumption of waterqoop heat pump system in China[J]. Applied Thermal Engineering, 2005, 25 (1) : 73-85.
  • 4Kavanaugh S P. Design considerations for water source heat pumps in southern climates [ J]. ASHRAE Transactions, 1989, 95(1): 1139-1149.
  • 5Reiley J S. Applications of closed loop water source heat pumps for space conditioning in commercial huildings[J]. Energy Engineering, 1990, 87(5): 6-16.
  • 6Hattemer B, Kavanaugh S P. Design temperature data for surface water heating and cooling systems [J ]. ASHRAE Transaction, 2005, ill(D: 695-701.
  • 7Chiasson A D, Spitler J D, Rees S J. A model for simulating the performance of a shallow pond as a supplemental heat rejecter with closed-loop ground source heat pump systems[J]. ASHRAE Transaction, 2000, 106(2); 107-121.
  • 8Soule J P. Closed loop water source heat pump system[J]. ASHRAE Journal, 1971, 13(9): 83-94.
  • 9ASHRAE. Systems and equipment handbook [M]. Atlanta: Society of heating, Refrigerating, and Air- Conditioning Engineers, 19 9 2 : 17 3-17 6.
  • 10陈瑾,张建忠.南京工程学院低能耗图书信息中心空调设计[J].江苏建筑,2008(2):46-47. 被引量:3