摘要 目的 观察尿液十项分析仪 (简称尿仪 )与显微镜检测 (简称镜检 )尿中红细胞的相关性。方法 住院患者送检的晨尿标本 1 4 2 1份 ,同时进行两种方法检测 ,将结果分析比较。结果 两种方法的总符合率为 85 4 % ,其中阴性完全符合率为 1 0 0 % ,阳性完全符合率为 1 4 8%。结论 尿仪检测的的敏感性明显高于镜检 ,尿仪检测BLD≤ 1 +,可忽略镜检 ;>1 +则必须镜检 ;明显不符时 ,应结合临床综合判断 。 AIM To observe the correlation of urine ten analysis apparatuses (abbreviation urine apparatus) and microscopic examination for middle red blood cell of urine. METHODS The patient being in hospital send morning checked up 1 421 of the specimen in the urine, and carries on at the same time two kinds of methods testing, and compares the interpretation of result. RESULTS The complete rate fitting of the among them negative completely rate fitting of the rate fitting always of two kinds of methods for 85 4%, for 100%, s masculine is 14 8%. CONCLUSIONS Urine apparatus the person who tests clear more than looking glass of sensitivity is checked up. Urine apparatus checkout BLD ≤ 1+, can neglect the looking glass checking up But >1+ must be checked up by the looking glass Should combine the clinical synthetical judgement when clearly not agreeing with, and the doctor keeps the contact when necessary.
作者 董万忠
出处 《安徽医药》 CAS 2004年第1期36-37,共2页 Anhui Medical and Pharmaceutical Journal
关键词 干化学法 镜检法 检测 尿 红细胞 相关性 符合率 the urine apparatus the looking glass is checked up red blood cell the fitting rate
  • 相关文献

参考文献3

二级参考文献3

共引文献67

同被引文献22

  • 1胡望平,胡盈莹,黄兢姚,张荣盛,冯福英.尿红细胞镜检血浆血红蛋白与尿液试条潜血的探讨[J].第三军医大学学报,2005,27(18):1899-1900. 被引量:8
  • 2胡望平,胡盈莹,王海林,周长邵,陈云飞,陈素双,黄爱娥,兰小鹏.显微镜血尿作为泌尿道肿瘤的筛查程序[J].中国实验诊断学,2006,10(2):180-181. 被引量:3
  • 3高晓燕,胡盈莹,胡望平,冯福英,陈素双.女性尿红细胞参考值及其在泌尿生殖系统肿瘤诊断中的意义[J].福建医药杂志,2007,29(3):120-122. 被引量:1
  • 4Zahur Z, Sylvie R, Jan V. Unsatisfactory performance of flow cytometer UF-100 and urine strips in predicting outcome of urine cultures. J Clin Mierobio ,2001,39:4169.
  • 5Delanghe JR, Kouri TT, Huber AR, et al. The role of automated urine partied flow cytometry in clinical practice. Clin Claim Acta,2003,301:1-18.
  • 6Jonathan BE,Linda B,Richared AM.Evaluation of the Sysmex UF.100 automated urinalysis analyzer[J].Clin Chem,1998,44:92.
  • 7Chien TI,Kao JT.Urine sediment examination:A comparison of automated urinalysis systems and manual microscopy[J].Clin Chim Acta,2007,384(1/2):28-34.
  • 8胡望平.血浆游离Hb[A].见:总后勤部卫生部编.医疗护理技术操作常规[M]第4版[C].,1998.1847.
  • 9Hofland C A, Mariani A J. Is cytology required for a hematuria evaluation [J]? J Urol, 2004, 171(1): 324-326.
  • 10Grossfeld G D, Wolf J S Jr, Litwan M S, et al. Asymptomatic microscopic hematuria in adults: summary of the AUA best practice policy recommendations[J]. Am Fam Physician, 2001, 63(6): 1145 -1154.

引证文献4

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部