期刊文献+

BEPCⅡ BPM模拟研究 被引量:2

Simulation of BEPCⅡ′s BPM
原文传递
导出
摘要 基于减少光电子的要求 ,BEPCⅡ真空管道采用antechamber结构 ,TE模截止频率可能低于BPM信号处理频率 5 0 0MHz .本文主要模拟研究TE10 模对位置测量的影响 ,发现TE10 模截止频率低于 5 0 0MHz时 ,将带来束流位置测量误差 10 .1μm ;改变狭缝长度 ,在TE10 模截止频率高于 5 0 0MHz时 ,测量误差将在可以接受的范围内 .同时 ,模拟研究了BPM尾场对束流的影响 。 Considering the effect of photoelectron, BEPCⅡ′s beam position monitor (BPM) uses antechamber structure. The cut-off frequency of TE mode is maybe lower than the BPM signal processing frequency 500MHz. The power of TE mode will result in beam position measurement error. With monitoring the antechamber's TE mode power amplitude and calculating the transmission of TE mode power to BPM's electrodes, we can calculate the error of position measurement caused by TE mode. We found that the error is beyond the acceptance when the cut-off frequency of TE 10 mode is lower than 500MHz. By changing the slot length, the cut-off frequency is higher than 500MHz and the error could be accepted. At last the effect of the wakefield to the beam has been simulated and the longitudinal impedance of wakefield has been calculated.
出处 《高能物理与核物理》 CSCD 北大核心 2004年第6期664-668,共5页 High Energy Physics and Nuclear Physics
关键词 BPM 截止频率 尾场 阻抗 BEPCⅡ真空管道 TE模 截止频率 测量误差 电子云 BPM, TE 10 mode, TE cut-off frequency, wakefield, impedance
  • 相关文献

参考文献4

  • 1Corlett J,Ng C-K,Smith S-R.Effect of TE Mode Power on the PEP ⅡLER BPM System.In: Proc.of PAC97.Vancouver: 1997.2116-2118
  • 2MA Li,SHI Ping,YE Kai-Rong.HEP & NP,1998,22(5) :475-480(in Chinese)(马力,石平,叶恺容.高能物理与核物理,1998,22(5):475-480)
  • 3Ng C-K,Weiland T,Martin D et al.Simulation of PEP- Ⅱ Beam Position Monitors.In: Proc.of PAC95.Dallas: 1995.2485-2487
  • 4廖承恩.微波技术基础[M].西安:西安电子科技大学出版社,2001.74.

同被引文献12

  • 1Slaton T.Development of Nanometer Resolution C-Band Radio Frequency Beam Position Monitors in the Final Focous Test Beam.In:Proc.of LINAC98.Chicago:1998.911-913
  • 2Emma P.Nucl.Instrum.and Methods,1999,A429:407-413
  • 3Marc C R.Future Developments in Electron Linac Diagnostics.In:Proc.of LINAC2004.Lübeck:2004.280-284
  • 4Waldmann H.Cavity-Type BPMs for the Tesla Test Facility Free Electron Laser.In:Proc.of DIPAC2003.Mainz:2003.193-195
  • 5Shintake.Development of Nanometer Resolution RFBPMs.In:Proc.of HEACC98.Dubna:1998.133-135
  • 6Ronald Johnson.An X-Band Cavity for a High Precision Beam Position Monitor.In:Proc.of DIPAC2003.Mainz:2003.196-198
  • 7Lorenz R.Cavity Beam Position Monitors.In:Proc.of PAC2003.Ptland:2004; In:Proc.of AIP98.Poland:1998.26-58
  • 8Ross M C et al.Very High Resolution RF Cavity BPM.In:Proc.of PAC2003.Ptland:2004.2545-2547
  • 9Sabah S.Design and Calibration of IQ-Mixers,EPAC 1998.830-832
  • 10罗箐,孙葆根,何多慧,卢平,王晓辉,方佳.新型跑道腔式束流位置监测器[J].强激光与粒子束,2010,22(7):1635-1639. 被引量:2

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部