摘要 维持性血液透析患者并发症中营养不良发生率较高,且常常预示高住院率及高死亡率。及时评估血透患者的营养状况并给予干预,对提高患者的生活质量及改善长期预后有着重要意义。生物电阻抗技术在维持性血液透析患者营养状况评估中具有可操作性、重复性强、且为无创检查、可对人体体内成分的各种指标实现定量分析等诸多优点,患者容易接受,且能够长期监测血液透析患者的营养状况,及早发现营养不良,有助于早期开展高危患者的营养干预及干预效果的动态评价,现已在临床上应用。本文旨在对维持性血液透析患者的营养现状及生物电阻抗技术在评估维持性血液透析患者营养状况中的应用进行综述。 The incidence of malnutrition is high in complications in patients with maintenance hemodialysis, and often indicates high hospitalization rate and high mortality. Timely evaluate the nutritional status of blood absorbing patients, which has important significance for improving the quality of life and improving long-term prognosis. Biological impedance technology has its operability, repetitiveness, strong recipient, and non-invasive inspections, and has a variety of indexes of the individual components of the human body, and patients are easily accepted. It is possible to monitor the nutritional status of blood dialysis patients, and early detection of malnutrition, which helps to develop a dynamic evaluation of nutritional intervention and intervention effects in early high-risk patients. It is now used in clinical practice. This paper aims to review the nutritional status and bioelectric impedance techniques for the maintenance hemodialysis patients to evaluate the application of the nutritional conditions in maintaining hemodialysis patients.
作者 刘江杰 梅峰
出处 《临床医学进展》 2021年第5期2398-2404,共7页 Advances in Clinical Medicine
  • 相关文献

参考文献15

二级参考文献92

  • 1陈江华,何强,徐莹.维持性血液透析患者微炎症状态的认识与防治[J].中华肾脏病杂志,2005,21(2):117-118. 被引量:146
  • 2吴国豪,刘中华,全应军,吴肇汉.普外科住院患者营养状况评价[J].中华普通外科杂志,2004,19(12):732-734. 被引量:34
  • 3林善锬,谌贻璞,钱家麒,陈香美,刘志红,顾勇,梅长林,陈楠,李学旺,章友康,王力宁,黄颂敏,余学清,袁伟杰,郑法雷,王梅,潘长玉,杨文英,翁建平.慢性肾脏病蛋白营养治疗共识[J].实用糖尿病杂志,2005,1(5):3-6. 被引量:25
  • 4刘惠兰.维持性血液透析患者的营养问题[J].中国血液净化,2006,5(10):703-706. 被引量:32
  • 5Mineshima M,Ishimori I,Sakiyama R.Validity of internal filtration-enhanced hemodialysis as a new hemodiafiltration therapy[J].Blood Purif,2009,27(1):33-37.
  • 6Susantiaphong P,Tirnathanagul K,Katavetin P,et al.Efficacy of convective-controlled double high-flux hemodiafiltration versus on-line hemodiafiltration:1-year prospective study[J].Blood Purif,2010,29(1):35-43.
  • 7Fissell WH,Humes HD,Fleischman AJ,et al.Dialysis and nanotechnology:now,10 years,or never?[J] Blood Purif,2007,25(1):12-17.
  • 8Attaluri AC,Huang Z,Belwalkar A,et al.Evaluation of nano-porous alumina membranes for hemodialysis application[J].ASAIO J,2009,55(3):217-223.
  • 9Ronco C,Breuer B,Bowry SK.Hemodialysis membranes for high-volume hemodialytic therapies:The application of nanotechnology[J].Hemodial Int,2006,10(s1):S48-50.
  • 10Stamopoulos D,Bouziotis P,Benaki D,et al.Nanobiotechnology for the prevention of dialysis-related amyloidosis[J].Ther Apher Dial,2009,13(1):34-41.

共引文献233

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部