术中神经电生理监测技术作为保护神经功能的常规手段已经得到普遍认可,但目前国内关于术中行神经电生理监测出现并发症的病例报道却几乎没有,如何预防相关并发症的发生也暂缺明确的统一标准,现我们报道一例术中行神经电生理监测导致患者口唇损伤病例,以提高临床医生对神经电生理监测并发症的重视及预防意识。
Intraoperative neuroelectrophysiological monitoring technology has gained widespread recognition as a standard method for safeguarding nerve function. However, in China, there have been scarce reports of complications arising from intraoperative neuroelectrophysiological monitoring, and a lack of clear unified standards on how to prevent such complications. Herein, we present a case in-volving lip bite injury caused by intraoperative neuroelectrophysiological monitoring to enhance awareness among clinical doctors regarding the prevention and management of complications as-sociated with neuroelectrophysiological monitoring.