摘要 心率是脉搏波的最基本信息,是人体健康的一项重要生理指标。传统的心率检测多与人体有直接接触,而长时间的接触会造成被试者的不适,因而不适合长时间的心率测量。因此本文提出了利用摄像头实现非接触式对被测者的光电容积脉搏波(RPPG: remote Photo Plethysmography)的提取和分析的方法。即基于人脸识别技术,实现从摄像头中自动分割被测试者的面部信息,选取感兴趣区域(ROI: Region of Interest),使用计算机视觉技术和独立成分分析算法(ICA: Independent ComponentAnalysis),从摄像头视频中提取被测者的光电容积脉搏波信号。本文设计实现了非接触式测量心率,提供了一种较为准确的心率测量方法。 Heart rate is the most basic information ofpulse wave and an important physiological index of human health.Traditionalheart rate measurement is mostly in direct contact with the human body,andprolonged contact will cause discomfort to the subjects,so it is not suitablefor long-term heart rate measurement.Therefore,this paper proposes a methodfor the extraction and analysis of non-contact Remote Photo Plethysmography(RPPG)of the subject using the camera.That is,based on face recognitiontechnology,the facial information of the testee can be automatically segmentedfrom the camera,and Region of Interest(ROI)can be selected.In this paper,computer vision technology and Independent Component Analysis(ICA)are used toextract the photoelectric volume pulse wave signal of the subject from thecamera video.The design realizes the non-contact heart rate measurement andprovides a more accurate heart rate measurement method.
机构地区 天津工业大学
出处 《生物医学》 CAS 2019年第3期121-127,共7页 Hans Journal of Biomedicine
  • 相关文献

参考文献3

二级参考文献24

  • 1张建明,林亚平,吴宏斌,杨格兰.独立成分分析的研究进展[J].系统仿真学报,2006,18(4):992-997. 被引量:31
  • 2李镒冲,李晓松.两种测量方法定量测量结果的一致性评价[J].现代预防医学,2007,34(17):3263-3266. 被引量:154
  • 3POH M Z,MCDUFFDJ, PICARD R W. Non-contact, au-tomated cardiac pulse measurements using video imaging andblind source separation [J].Opt Express, 2010, 18(10):10762-10774.
  • 4罗志昌,张松,杨益民,等.光电容积脉搏描记法原理及其在临床上的应用[J].世界医疗器械,2000,16(9) :41-47.
  • 5阮锦新,尹俊勋.基于人脸特征和八如800对算法的多姿态人脸检测[J].计算机应兩,2010,30(4) :967-970.
  • 6Scully C G, Jinseok L, Meyer J, et al. Physiological param- eter monitoring from optical recordings with a mobile phone ~J]. IEEE Transactions on Biomedical Engineering, 2012, 59 (2) : 303-306.
  • 7Allen J. Photoplethysmography and its application in clinical physiological measurement [ J]. Physiol Meas, 2007, 28 (3) : 1-39.
  • 8Poh M Z, McDuff D J, Picard R W. Advancements in non- contact, muhiparameter physiological measurements using a webcam[ J]. IEEE Transactions on Biomedical Engineering, 2011, 58(1) : 7-11.
  • 9Huang N E. The empirical mode decomposition and the Hil- bert spectrum for nonlinear and non-stationary time series analysis [ J ]. Royal Society of London Proceedings, 1998, 454(1971) : 903-995.
  • 10Hyv~ rinen A, Karhunen A, Oja E. Independent Component Analysis[ MI. John Wiley & Sons, 2001.

共引文献22

同被引文献5

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部