期刊文献+

低温等离子体去除氯苯的研究 被引量:1

Study on Chlorobenzene Removal by Low-Temperature Plasma
下载PDF
导出
摘要 本文以氯苯为目标污染物,利用低温等离子体处理氯苯,考察了放电过程中的电学特性、不同气量对低温等离子体去除氯苯效果的影响、CO2产生以及副产物(O3和NOx)产生情况。结果表明:放电时,外加电压在−17,500 V^7500 V之间呈周期性波动,放电电流峰谷值在−0.3 A~−0.2 A范围内。放电功率和氯苯去除效率均随着放电时间的延长而逐步增加直至稳定,放电功率稳定在6.8 W左右,氯苯去除率稳定在72%左右。反应生成的CO2 浓度也随着放电时间的延长而逐步增加并趋于稳定,达到1170 ppm。氯苯的降解效率随气量的增加而减小,当气量从500 mL/min增加到1500 mL/min时,在峰电压稳定在27 kV时氯苯的降解效率从74.43%降低到51.92%。 In this paper, chlorobenzene was treated by low-temperature plasma with chlorobenzene as the target pollutant. The electrical characteristics of the discharge process, the influence of different gas volume on the removal of chlorobenzene by low temperature plasma, the production of CO2 and the production of by-products (O3 and NOx) were investigated. The results show that the applied voltage fluctuates periodically from −17,500 V to 7500 V, and the peak to valley value of discharge current is in the range of −0.3 A~−0.2 A. The discharge power and the removal efficiency of chlorobenzene increased gradually with the prolongation of discharge time until stable. The discharge power was stable at about 6.8 W, and the chlorobenzene removal rate was stable at about 72%. The concentration of CO2 generated by the reaction increased with the discharge time and tended to be stable at 1170 ppm. The degradation efficiency of chlorobenzene decreased with the increase of gas volume. When the gas volume increased from 500 mL/min to 1500 mL/min, the degradation efficiency of chlorobenzene decreased from 74.43% to 51.92% when the peak voltage was stable at 27 kV.
机构地区 浙江树人大学
出处 《化学工程与技术》 CAS 2020年第5期335-343,共9页 Hans Journal of Chemical Engineering and Technology
关键词 等离子体 氯苯 降解 副产物 Plasma Chlorobenzene Degradation By-Product
  • 相关文献

参考文献8

二级参考文献84

  • 1羌宁,季学李,都基峻,何坚.苯系混合气体生物滴滤器非稳态工况性能[J].环境科学,2005,26(1):16-19. 被引量:10
  • 2谢绍东,于淼,姜明.有机气溶胶的来源与形成研究现状[J].环境科学学报,2006,26(12):1933-1939. 被引量:67
  • 3袁贤鑫等.催化燃烧法治理有机废气[J].化工环保,1984,4(4):219-225.
  • 4K Urashima, J S Chang. Removal of volatile organic compounds from airstreams and industrial flue gas by non-thermal plasma tecimology[J]. IEEE Trans. Dielectr. Insulat,2000, 7(5): 602-614.
  • 5TOda. Non-thermal plasma precessing for environmental protection: decomposition of dilute VOCs in air [J].Journal of Electrostatics, 2003, 57:293-311.
  • 6[2]Zhou Yuanxiang. An investigation on pulse discharge effect on the surface chemical transformation of fly ash [J].Thin Solid Films, 2001, 386:195-199.
  • 7[4]Oda T. Non-thermal plasma processing for environmental protection: decomposition of dilute VOCs in air [J].Journal of Electrostatics, 2003, 57:293-311.
  • 8Chang J S. Energetic Electron Induced Plasma for Reduction of Acid and Greenhouse Gases in Combustion Flue Gas. In No-Thermal Plasma Technologies for Pollution Control: Part A, Berlin:Springer, 1993.
  • 9James T Yeh, Warren T Ma et al. Integrated testing of the NOx SO2 process: simultaneous removal of SO2 and NOx from flue gas. Chem. Eng. Comm., 1992, 114:65--88.