摘要
本文依据环氧乙烷检测仪的原理和应用,提出了环氧乙烷检测仪的计量校准方法,对计量特性、校准条件、校准项目和校准方法进行探讨。并对校准项目包括外观检查、示值误差、重复性、响应时间进行了详细的论述。本文描述的环氧乙烷检测仪的校准方法及结果评价将为相关仪器的校准提供一个良好的指导,从而保证未来的测量结果准确可比,量值可溯源。
Based on the principle and application of the ethylene oxide detector,this paper puts forward the measurement calibration method of the ethylene oxide detector,and discusses the measurement characteristics,calibration conditions,calibration items and calibration methods.The calibration items including appearance inspection,indication error,repeatability and response time are dis-cussed in detail.The calibration method and result evaluation of the ethylene oxide detector de-scribed in this paper will provide a good guidance for calibration of related instruments,and ensure the accuracy and comparability of future measurement results and traceability of quantities.
出处
《仪器与设备》
2019年第1期53-57,共5页
Instrumentation and Equipments
基金
广东省质量技术监督局科技项目(2018ZJ02).