摘要
本文主要讲述了WindObserver 75超声风传感器频繁掉线的现象,分析风传感器因掉线而风数据丢失的原因,从风传感器,电源质量,供电、通信线路、外界环境等方面进行分析和处理,经过不断的整改和测试,总结得出故障原因是强弱电共管,因网管资源条件有限,将电信号转为光信号与强电共管,成功解决故障。
This paper mainly describes the phenomenon of frequent disconnection of WindObserver 75 ul-trasonic wind sensors, analyzes the causes of wind data loss due to disconnection of wind sensors, analyzes and deals with wind sensors, power quality, power supply, communication lines, external environment, etc. After continuous rectification and testing, it is concluded that the fault is caused by strong and weak electric co-management. Due to the limited network management resources, the electrical signal is converted into the optical signal and co-managed with strong electricity, successfully resolving the fault.