摘要
将鸟类栖息筑巢对变电站的影响减少到最低限度,是变电站工作人员共同关注的问题。本文首先通过近几年调研的数据对深圳电网的变电站鸟害特点进行分析,总结出变电站鸟害发生的时间规律、鸟害发生地的区域特点以及鸟害发生设备结构特征;其次归纳对比了各领域的防鸟害技术手段,为变电站防鸟害提供借鉴意义;最后提出了今后变电站防鸟害工作的研究方向和建议。
It is the common concern of substation staff to minimize the impact of birds nesting on the substation. In this paper, the characteristics of bird damage in substation of Shenzhen power grid are analyzed based on the survey data in recent years, and the time rule of bird damage in substation, the regional characteristics of bird damage place and the structural characteristics of bird damage equipment are summarized. Secondly, the technical means of bird prevention in various fields are summarized and compared to provide reference for substation bird prevention. Finally, the research direction and suggestions of bird prevention work in substation in the future are put forward.
出处
《电气工程》
2022年第1期39-49,共11页
Journal of Electrical Engineering