摘要 本文中,我们采用试验方法对核级应急柴油发电机组进行抗震鉴定。使用连续白噪声方法,测得机组在三正交轴上的固有频率和阻尼比。根据业主提供的楼板反应谱,生成人工地震波,对机组三正交轴向同时输入模拟地震加速度时程进行激振,分别进行了5次OBE (运行基准地震)和1次SSE (安全停堆地震)地震模拟振动台试验,试验表明机组各项性能指标在抗震试验前后无明显变化,抗震性能满足要求。 In this paper, we do the seismic identification of nuclear emergency diesel generator by test method. Dynamic characteristics including orthogonal tri-axial fundamental frequencies and equivalent damping ratios were measured by using the white noise scanning method. Artificial seismic waves were generated according to the floor acceleration response spectrum provided by the owners. Furthermore, five OBE and one SSE shaking table tests for emergency diesel generator were done by using the artificial seismic waves as seismic inputs along the orthogonal tri-axial simultaneity. The results show that the emergency diesel generator satisfies the seismic requirements and there is no obvious change of its performances before and after the earthquake test.
出处 《声学与振动》 2015年第4期38-45,共8页 Open Journal of Acoustics and Vibration
  • 相关文献

参考文献2

二级参考文献14

  • 1刘永昌 等.P300核机空气处理抗震试验鉴定[M].国家地震局工程力学研究报告,1995..
  • 2孙柏涛,刘永昌,高登琛,任守宇.巴基斯坦恰希玛核电站用 P300 工程核级离心通风机抗震性能计算及试验研究[J].地震工程与工程振动,1997,17(1):89-94. 被引量:6
  • 3杨仁安 赵国玺.核电站1E级设备的抗震鉴定试验.核动力工程,1988,:23-28.
  • 4刘永昌,国家地震局工程力学研究所报告,1995年
  • 5核电厂抗震设计规范
  • 6核设备抗震鉴定试验指南
  • 7中华人民共和国建设部.GB50267-97核电厂抗震设计规范[S].北京:中国标准出版社,1997.
  • 8国家核安全局.HAF J0053-1995.核设备抗震鉴定试验指南[S].北京,1995.
  • 9国家技术监督局.GB13625-92核电厂安全系统电气设备抗震鉴定[S].北京:中国标准出版社.1992.
  • 10IEEE Standard 344-1987. IEEE Recommended prac- tice for seismic qualification of class 1E equipment for nuclear power generating stations [ S ]. New York: The Institute of Electrical and Electronic Engineers, Inc. ,1987.

共引文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部