中美变电站隔离开关抗震设防规范的研究

Comparative Study on Seismic Code of the Disconnect Switch between Chinese and American Standard
下载PDF
导出
摘要 为研究我国电力设备抗震设计规范的适用性,通过研究中美电气设备的抗震设防标准,对比分析了电气设备的分类、设防目标、设防水准等方面之间的差异,提出了我国相关规范的特点。并以隔离开关和接地开关为例,阐述了它的操作要求、评定方法、评定步骤、设计要求和报告内容等。通过美国变电站抗震设防标准的分析研究,借鉴其先进的抗震设计理论,提出了修订我国电气设备抗震设计的建议。 In order to study the applicability of Chinese code for seismic design of electrical equipment, we comparatively analyze the seismic performance goal and level of electrical equipment between Chinese and American standard. As a case study of disconnect and grounding switch, its operation requirements, assessment method, assess steps, design requirement and more are expounded. Through the analysis and study of substation seismic fortification standards, this paper puts forward related suggestions on the revision of our country’s seismic design of electrical equipment.
出处 《智能电网(汉斯)》 2017年第1期1-8,共8页 Smart Grid
基金 国家电网科技项目(SGRI-WD-71-15-010)。
  • 相关文献

参考文献5

二级参考文献72

  • 1沈建文,石树中.大中小震与抗震设防标准[J].地震学报,2004,26(5):533-538. 被引量:18
  • 2周锡元 王广军 等.场地分类和平均反应谱[J].岩土工程学报,1984,6(5):59-68.
  • 3GB50260-96电力设施抗震设计规范[S].北京:中国建筑工业出版社,1996.
  • 4GB18306--2001,中国地震动参数区划图[S].
  • 5于永清.四川电网汶川地震电力设施受灾调研分析.电网技术,2008,32(11):1-6.
  • 6GB/T13540-92高压开关设备抗震性能试验[S].北京:中国标准出版社,1992.
  • 7工业企业电气设备抗震设计规范(报批稿),2008.
  • 8JEAG5003-2008电气设备抗震设计指南[S].日本,1998.
  • 9IEEE Standard 693. Recommended Practice for Seismic Design of Substations [S]. Institute of Electrical and Electronic Engineers, USA, 2005.
  • 10Shakhzod M Takhirov, Gregory L Fenves, Fujisaki Eric. Ground motions for earthquake simulator qualification of electrical substation equipment [R].PEER-2004/07, Pacific Earthquake Engineering Research Center, University of California, Berkeley, USA, 2005.