期刊文献+

Corrosion Prevention of the Generator Stator Hollow Copper Conductor and Water Quality Adjustment of Its Internal Cooling Water 被引量:2

Corrosion Prevention of the Generator Stator Hollow Copper Conductor and Water Quality Adjustment of Its Internal Cooling Water
下载PDF
导出
摘要 On the basis of expounding the corrosion mechanism of the stator hollow copper conductor in the water-cooling generator, methods of preventing corrosion of the stator hollow copper conductor in the wa-ter-cooling generator through adjusting water quality of its cooling water have been proposed. For internal water cooling systems which are airtight, the corrosion of the hollow copper conductor can be prevented through keeping foreign oxygen and carbon dioxide from entering the system, and the amount of oxygen in the internal water can be lowered by blowing high purity nitrogen. For systems not airtight, the corrosion of the hollow copper conductor can be inhibited through lowering the amount of oxygen to some extent by sealing and increasing pH value by processing part of cooling water with bypass small flow sodium-type mix-bed. On the basis of expounding the corrosion mechanism of the stator hollow copper conductor in the water-cooling generator, methods of preventing corrosion of the stator hollow copper conductor in the wa-ter-cooling generator through adjusting water quality of its cooling water have been proposed. For internal water cooling systems which are airtight, the corrosion of the hollow copper conductor can be prevented through keeping foreign oxygen and carbon dioxide from entering the system, and the amount of oxygen in the internal water can be lowered by blowing high purity nitrogen. For systems not airtight, the corrosion of the hollow copper conductor can be inhibited through lowering the amount of oxygen to some extent by sealing and increasing pH value by processing part of cooling water with bypass small flow sodium-type mix-bed.
机构地区 不详
出处 《Energy and Power Engineering》 2009年第1期17-20,共4页 能源与动力工程(英文)
关键词 GENERATOR INTERNAL cooling-water HOLLOW COPPER conductor corrosion and protection generator internal cooling-water hollow copper conductor corrosion and protection
  • 相关文献

参考文献1

二级参考文献4

  • 1DL/T561-95.火力发电厂水汽化学监督导则[S].[S].,..
  • 2DL/T801-2002.大型发电机内冷却水质及系统技术要求[S].
  • 3GB/T 12145-1999,火力发电机组及蒸汽动力设备水汽质量标准[S].
  • 4汽轮发电机运行规程[M].1999年版.北京:中国电力出版社,2000.29.