Study on Short Circuit Current Calculation of Power System with UHVDC and New Energy Source

Study on Short Circuit Current Calculation of Power System with UHVDC and New Energy Source
下载PDF
导出
摘要 With the development of power system, the level of short circuit current will increase accordingly. In general, the influence of the HVDC system and the new energy source is not considered in the calculation of the short circuit current. For the power grid that short circuit current level closes to the interrupting capacity of circuit breaker, it’s necessary to fully consider all kinds of influence factors, careful checking, so as to obtain more accurate calculation results of short circuit current. In 2018, two ±800 kV high-power Ultra High Voltage Direct Current (UHVDC) transmission projects will be connected with Shaanxi power grid, accompanied by a lot of concomitant fossil-fuel generating plants as power resource, and also a large number of new energy source, includes wind power generation and photovoltaic power generation. Around one of the UHVDC converter stations, short circuit current may exceed the withstand limit of some certain circuit breakers. In order to get more accurate short circuit current calculation results, three measures are used: 1) contrastive calculation and analysis by algorithm based on schemes and algorithm based on power flow;2) analysis the influence of UHVDC by electromagnetic transient and electromechanical transient hybrid simulation;3) considered a detailed model of Doubly Fed Induction Generator (DFIG) with low voltage ride through characteristics. The calculation results shows that: in the typical operation mode of Shaanxi power grid of 2018, the original calculation results by conventional calculation method are coincident with the results by considering the influence of algorithms, UHVDC and DFIG in large, in which: the results of the algorithm based on power flow are smaller than that of the algorithm based on schemes about 2 - 8 kA;the steady values of the short circuit current provided by UHVDC converterstation (includes rectifiers and smoothing capacitors) are about 0 - 3 kA;the steady values of the short circuit current provided by DFIG are about 0 - 5 kA. The calculation results can provide reference for the selection of the circuit breaker, and it can be verified by fault recording data in the future. With the development of power system, the level of short circuit current will increase accordingly. In general, the influence of the HVDC system and the new energy source is not considered in the calculation of the short circuit current. For the power grid that short circuit current level closes to the interrupting capacity of circuit breaker, it’s necessary to fully consider all kinds of influence factors, careful checking, so as to obtain more accurate calculation results of short circuit current. In 2018, two ±800 kV high-power Ultra High Voltage Direct Current (UHVDC) transmission projects will be connected with Shaanxi power grid, accompanied by a lot of concomitant fossil-fuel generating plants as power resource, and also a large number of new energy source, includes wind power generation and photovoltaic power generation. Around one of the UHVDC converter stations, short circuit current may exceed the withstand limit of some certain circuit breakers. In order to get more accurate short circuit current calculation results, three measures are used: 1) contrastive calculation and analysis by algorithm based on schemes and algorithm based on power flow;2) analysis the influence of UHVDC by electromagnetic transient and electromechanical transient hybrid simulation;3) considered a detailed model of Doubly Fed Induction Generator (DFIG) with low voltage ride through characteristics. The calculation results shows that: in the typical operation mode of Shaanxi power grid of 2018, the original calculation results by conventional calculation method are coincident with the results by considering the influence of algorithms, UHVDC and DFIG in large, in which: the results of the algorithm based on power flow are smaller than that of the algorithm based on schemes about 2 - 8 kA;the steady values of the short circuit current provided by UHVDC converterstation (includes rectifiers and smoothing capacitors) are about 0 - 3 kA;the steady values of the short circuit current provided by DFIG are about 0 - 5 kA. The calculation results can provide reference for the selection of the circuit breaker, and it can be verified by fault recording data in the future.
出处 《Energy and Power Engineering》 2017年第4期625-634,共10页 能源与动力工程(英文)
关键词 SHORT CIRCUIT CURRENT UHVDC New Energy SOURCE Hybrid Simulation Short Circuit Current UHVDC New Energy Source Hybrid Simulation
  • 相关文献

参考文献1

二级参考文献17

  • 1迟永宁,刘燕华,王伟胜,陈默子,戴慧珠.风电接入对电力系统的影响[J].电网技术,2007,31(3):77-81. 被引量:499
  • 2常勇,徐政,郑玉平.大型风电场接入系统方式的仿真比较[J].电力系统自动化,2007,31(14):70-75. 被引量:48
  • 3李全林.新能源与可再生能源[M].南京:东南大学出版社,2009.
  • 4Chen Z, Blaabjerg F. Wind farm--a power source in future power systems[J]. Renewable and Sustainable Energy Reviews, 2009, 13(6-7): 1288-1300.
  • 5Chai Chompooinwai, Lee Wei Jen. System impact study for the interconnection of wind generation and utility system[J]. IEEE Transactions on Industry Applications, 2005, 41(1): 163-168.
  • 6Shimy El M, Badr M A L, Rassem O M. Impact of large scale wind power on power system stability[C]. Power System Conference, MEPCON, 12th International Middle-East, 2008.
  • 7Slootweg J G, Kling W L. The impact of large scale wind power generation on power system oscillations[J]. Electric Power Systems Research,2003, 67(1): 9-20.
  • 8Clemens Jauch, Poul Sφrensen, Ian Norheim, et al. Simulation of the impact of wind power on the transient fault behavior of the Nordic power system[J] Electric Power Systems Research, 2007, 77(2): 135-144.
  • 9Sheng Dakai, Dai Huizhu, Chen Mozi, et al. Discussion of wind farm integration in China[C]. Transmission and Distribution conference and Exhibition: Asia and Pacific, IEEE/PES, 2005.
  • 10Thiringer T. Power quality measurements performed on a low-voltage grid equipped with two wind turbines[J]. IEEE Trans. on Energy Conversion, 1996, 11(3): 601-606.

共引文献81

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部