Ground Subsidence Following Groundwater Drawdown by Excavating of 500 m Deep Investigation Shafts in Granite Body in Mizunami, Central Japan in 2004-2012

Ground Subsidence Following Groundwater Drawdown by Excavating of 500 m Deep Investigation Shafts in Granite Body in Mizunami, Central Japan in 2004-2012
下载PDF
导出
摘要 Two 500 m deep investigation shafts were excavating in the granite body in Mizunami, central Japan by JAEA (Japan Nuclear Cycle Development Institute) in 2004-2012. Groundwater with volume of 700 m3 was generally pumping a day to prevent the shafts from submerging in 2012 following the excavating. As a result of pumping the groundwater, the ground water level lowered to 60 m in the borehole with the distance of 200 m from the excavating shafts in 2012. Leveling network extending 2 km × 2 km around the shafts was established to detect the vertical deformation around the shafts in 2004, and precise leveling was done every year. An 18 mm ground subsidence was detected in the benchmark close to the shafts for 8 years in 2004-2012, and time series of subsidence at benchmark was consistent with the groundwater drawdown. The groundwater drawdown and ground subsidence were caused by the pumping ground water in excavating shafts. Two 500 m deep investigation shafts were excavating in the granite body in Mizunami, central Japan by JAEA (Japan Nuclear Cycle Development Institute) in 2004-2012. Groundwater with volume of 700 m3 was generally pumping a day to prevent the shafts from submerging in 2012 following the excavating. As a result of pumping the groundwater, the ground water level lowered to 60 m in the borehole with the distance of 200 m from the excavating shafts in 2012. Leveling network extending 2 km × 2 km around the shafts was established to detect the vertical deformation around the shafts in 2004, and precise leveling was done every year. An 18 mm ground subsidence was detected in the benchmark close to the shafts for 8 years in 2004-2012, and time series of subsidence at benchmark was consistent with the groundwater drawdown. The groundwater drawdown and ground subsidence were caused by the pumping ground water in excavating shafts.
出处 《Engineering(科研)》 2015年第7期424-433,共10页 工程(英文)(1947-3931)
关键词 Ground Subsidences GROUNDWATER DRAWDOWN 500 M DEEP EXCAVATION Shaft Precise LEVELING GROUNDWATER Drainage Ground Subsidences Groundwater Drawdown 500 m Deep Excavation Shaft Precise Leveling Groundwater Drainage
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部